{"product_id":"enerzone-destination-2-3-wood-insert","title":"Enerzone Destination 2.3 Wood Insert","description":"\u003cstyle\u003e\n  .km-desc, .km-desc * { box-sizing: border-box; max-width: 100%; }\n  .km-desc { width: 100%; }\n  .km-desc p { margin: 0 0 14px; }\n  .km-desc h3 { font-size: 11px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: 600; color: #9B774D; margin: 22px 0 10px; }\n  .km-desc .spec-list { margin: 12px 0 0; }\n  .km-desc .spec-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .spec-row:first-child { border-top: 1px solid rgba(75,72,75,0.35); padding-top: 14px; }\n  .km-desc .spec-label { font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; margin-bottom: 6px; }\n  .km-desc .spec-value { font-weight: 600; font-size: 15px; color: #231F20; margin-bottom: 6px; line-height: 1.35; }\n  .km-desc .spec-meaning { color: #4B484B; font-size: 13px; line-height: 1.55; }\n  @media (min-width: 720px) {\n    .km-desc .spec-row { display: grid; grid-template-columns: 38% 30% 1fr; gap: 16px; align-items: start; padding: 12px 0; }\n    .km-desc .spec-label { margin-bottom: 0; align-self: center; }\n    .km-desc .spec-value { margin-bottom: 0; font-size: 14px; align-self: center; }\n    .km-desc .spec-meaning { font-size: 13px; }\n    .km-desc .spec-row:first-child { padding-top: 12px; }\n  }\n  .km-desc .data-row { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding: 12px 0; border-bottom: 1px solid rgba(75,72,75,0.12); align-items: baseline; font-size: 13px; }\n  .km-desc .data-head + .data-row { border-top: 1px solid rgba(75,72,75,0.35); }\n  .km-desc .data-row .data-label { color: #4B484B; line-height: 1.4; }\n  .km-desc .data-row .data-val { font-weight: 600; color: #231F20; text-align: right; min-width: 56px; }\n  .km-desc .data-head { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding-bottom: 8px; font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; }\n  .km-desc .data-head span:nth-child(2), .km-desc .data-head span:nth-child(3) { text-align: right; min-width: 56px; }\n  .km-desc ul { list-style: none; padding: 0; margin: 10px 0 14px; }\n  .km-desc ul li { padding: 4px 0 4px 18px; position: relative; line-height: 1.55; }\n  .km-desc ul li:before { content: \"—\"; position: absolute; left: 0; color: #9B774D; font-weight: 500; }\n  .km-desc .compare-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .compare-row:last-child { border-bottom: 0; }\n  .km-desc .compare-name { font-weight: 600; color: #231F20; display: inline-block; padding-bottom: 1px; }\n  .km-desc .compare-orient { color: #4B484B; margin-top: 4px; font-size: 13px; line-height: 1.5; }\n  .km-desc .pull { font-style: italic; font-size: clamp(16px, 4.2vw, 22px); line-height: 1.4; color: #231F20; border-left: 2px solid #9B774D; padding: 0 0 0 16px; margin: 32px 0 16px; }\n  .km-desc .lede { font-size: clamp(16px, 4vw, 22px); line-height: 1.4; letter-spacing: -0.2px; font-weight: 400; color: #231F20; margin: 0 0 24px; }\n  .km-desc .warranty-note { font-size: 12px; color: #4B484B; font-style: italic; margin-top: 14px; }\n  .km-desc details { border-top: 1px solid rgba(75,72,75,0.18); margin: 0; padding: 0; }\n  .km-desc details:last-of-type { border-bottom: 1px solid rgba(75,72,75,0.18); }\n  .km-desc details \u003e summary { list-style: none; cursor: pointer; padding: 18px 32px 18px 0; position: relative; font-size: clamp(16px, 4.2vw, 20px); line-height: 1.3; font-weight: 500; color: #231F20; letter-spacing: -0.2px; }\n  .km-desc details \u003e summary::-webkit-details-marker { display: none; }\n  .km-desc details \u003e summary::after { content: \"+\"; position: absolute; right: 4px; top: 50%; transform: translateY(-50%); font-size: 22px; font-weight: 300; color: #9B774D; line-height: 1; }\n  .km-desc details[open] \u003e summary::after { content: \"−\"; }\n  .km-desc details \u003e summary:focus-visible { outline: 2px solid #9B774D; outline-offset: 4px; }\n  .km-desc details \u003e .acc-body { padding: 0 0 28px 0; }\n\u003c\/style\u003e\n\u003cdiv style=\"font-family: 'Inter', -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #231f20; line-height: 1.55; width: 100%; max-width: 100%; box-sizing: border-box; margin: 0; padding: 0; font-size: 16px; overflow-wrap: break-word; word-wrap: break-word; word-break: normal;\"\u003e\n\u003cdiv class=\"km-desc\"\u003e\n\u003cp class=\"lede\"\u003eA 2.4 ft³ non-catalytic medium-large wood insert designed for installation in an existing masonry fireplace — the Enerzone-tier contemporary cast-iron flush-mount option in the Destination line. EPA 2020 cordwood certified at 72% HHV efficiency, with a 20-inch maximum east-west log capacity, up to 2,100 sq ft of heating area, an 8-hour maximum burn time, 75,000 BTU\/hr maximum output, and a heat-activated 90 CFM blower included as standard.\u003c\/p\u003e\n\u003cdetails open=\"\"\u003e\n\u003csummary\u003eWho this is for\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003ch3\u003eRight buyer\u003c\/h3\u003e\n\u003cp\u003eOwners of a working masonry fireplace who want to convert an inefficient open hearth into a serious heat source — up to 2,100 sq ft of zone heating capability with a 2.4 ft³ firebox, 20-inch log capacity, and an 8-hour maximum burn cycle. Reasonable insulation, access to seasoned hardwood at 15–20% moisture, and an existing masonry fireplace that meets the minimum opening dimensions (23 3\/4\" H × 28 7\/8\" W × 19 5\/8\" D per manual) are the basic requirements.\u003c\/p\u003e\n\u003cp\u003eBuyers who want a contemporary aesthetic. The Destination 2.3 ships with a smooth cast-iron flush-mount surround designed to sit nearly flush with the masonry — a cleaner, more modern look than traditional louvered insert faces. The 35 7\/8\" × 25\" standard surround fits most modern masonry openings; optional backing plates extend the cover area for older or larger openings.\u003c\/p\u003e\n\u003cp\u003eBuyers who want a single appliance to do the work of zone heating across a main living area. The 14,200–44,500 BTU\/hr tested output band covers shoulder-season heating on the low end and serious cold-snap output on the high end. With the heat-activated 90 CFM blower, warm air circulates from the firebox jacket out into the room automatically once the insert is up to temperature.\u003c\/p\u003e\n\u003ch3\u003eWrong buyer\u003c\/h3\u003e\n\u003cp\u003eNot for buyers without an existing code-compliant masonry fireplace. Wood inserts must be installed inside a lined masonry fireplace with a continuous stainless-steel chimney liner running the full height. This insert is not approved for factory-built (prefab) metal fireplaces, mobile homes, or any installation outside a masonry hearth.\u003c\/p\u003e\n\u003cp\u003eNot for buyers expecting 10+ hour overnight burns. The 8-hour manufacturer maximum is achievable on a packed load of dense hardwood with the air shut down hard, but useful heat from a packed load is realistically 6–7 hours. For longer burns, step up to a 3.0+ ft³ firebox or consider catalytic technology.\u003c\/p\u003e\n\u003cp\u003eNot for buyers wanting traditional decorative cast-iron styling. The Destination 2.3 surround is intentionally clean and modern — sleek lines, minimal ornamentation, picture-frame proportions. Buyers wanting heavy decorative cast iron should look at the Osburn Matrix Insert (same platform, more traditional look) or premium-tier alternatives.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eAt a glance\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cdiv class=\"spec-list\"\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion technology\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eNon-catalytic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eSecondary-air tubes reignite smoke gases. No catalyst to replace; one air-control lever; simpler operation than a cat stove but shorter low-and-slow burn times.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eInstallation type\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eMasonry insert\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eInstalls inside an existing code-compliant masonry fireplace with a continuous stainless-steel chimney liner. Not approved for factory-built fireplaces, mobile homes, or freestanding installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFirebox volume\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e2.4 ft³ overall \/ 1.95 ft³ EPA\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Medium-large firebox sized for zone heating across 500–2,100 sq ft. The overall figure includes a buffer zone above the EPA loading line; the 1.95 ft³ figure is the usable loading volume used during EPA emissions certification.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum heat output\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e75,000 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePeak output on dry cordwood, transient. Sustained output across a burn cycle is substantially lower.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eTested output range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e14,200–44,500 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer CSA B415.1-10 stack-loss method. The realistic operating band buyers should plan around.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eHeating range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e500–2,100 sq ft\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer's stated range. Real-world comfort sizing for primary heat is roughly 1,200–1,800 sq ft in moderate climates and lower in cold climates or older homes — depends on insulation, layout, climate, ceiling height, fuel quality, and installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAverage efficiency\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e72% HHV \/ 77% LHV\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e79% optimum overall efficiency at low burn rate; 76% optimum heat transfer efficiency. HHV is the federal standard. Government incentives may apply by jurisdiction and installation date.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eParticulate emissions\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e2.3 g\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eEPA 2020 limits are 2.0 g\/hr crib-wood or 2.5 g\/hr cordwood. The insert is listed as compliant with the 2020 cordwood standard.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum burn time\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eUp to 8 hours\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer maximum at the lowest air setting. Useful heat through a burn cycle is realistically 6–7 hours.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eRecommended log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e16 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Most firewood suppliers cut to this length.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e20 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e4-inch margin over the recommended length — meaningful for buyers with access to longer-cut firewood. Logs load across the width of the firebox, sides visible from the door.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eCarbon steel, cast-iron surround\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eWelded carbon-steel firebox with a contemporary cast-iron flush-mount surround and arched cast-iron glazed door. Lifetime warranty on the combustion-chamber welds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eGlass door\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e18\" × 11 7\/8\", ceramic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eLarge arched ceramic glass with air-wash, 5\/32\" (4 mm) thick, tested to 1,400 °F. The picture-frame surround makes the glass the visual focus. Replacement glass must be a SCHOTT ceramic with the same specification — no substitute materials.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBlower\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eIncluded, 90 CFM heat-activated\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Heat-activated assembly with three-position switch: AUTO (starts when insert is hot, stops when cool), MANUAL (runs continuously), or OFF. Mounted on a drawer-style chassis behind the bottom faceplate for service access. Without the blower, heat distribution from an insert relies almost entirely on radiant heat through the glass — most of the firebox is enclosed in the masonry cavity, so the blower is what gets the heat into the room.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBaffle\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eC-Cast\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eRigid aluminosilicate fiber baffle rated above 2,000 °F.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFlue connection\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e6 in (insert liner)\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eTop of the unit. Requires a continuous stainless-steel chimney liner running the full height of the masonry chimney. Liner must conform to UL 1777 (USA), CAN\/ULC-S635, or CAN\/ULC-S640 (Canada). Per manual, minimum chimney height 12 feet. Sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion chamber\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e21\" W × 16 3\/4\" D × 11 7\/8\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eInside firebox dimensions per manufacturer spec. Wider than deep; the 16 3\/4\" depth is generous enough to accept N-S loading for packed cold-weather cycles in addition to the default E-W loading.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eDoor opening\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e17 1\/2\" W × 8 3\/4\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eLoading door opening. The wide door accommodates 20-inch logs loaded east-west.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMinimum masonry opening\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e23 3\/4\" H × 28 7\/8\" W × 19 5\/8\" D\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Confirm fireplace dimensions before ordering. See \"Where it can go\" for backing plate and projection kit options.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eShipping weight\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e478 lb (without option)\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Appliance weight installed: 422 lb. Plan for professional installation — this is heavy work in a confined space.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCountry of origin\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eMade in Canada\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufactured by Stove Builder International (SBI) in Saint-Augustin-de-Desmaures, Quebec.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhere it can go\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cp\u003eThe Destination 2.3 Insert is approved only for installation inside an existing code-compliant masonry fireplace with a continuous stainless-steel chimney liner. It is not approved for installation in factory-built (prefab) metal fireplaces, in mobile or manufactured homes, in alcoves, or as a freestanding unit. The masonry fireplace and chimney must be inspected before installation for cracks, loose mortar, creosote, blockage, or other signs of deterioration.\u003c\/p\u003e\n\u003ch3\u003eMinimum masonry opening\u003c\/h3\u003e\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eDimension\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eMin\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eHeight\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e23 3\/4\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eWidth\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e28 7\/8\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eDepth\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e19 5\/8\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 14px;\"\u003eIf a fresh-air intake is being installed, add a minimum of 4 inches to the width. Plan for a small installation margin above the insert to seat the liner adapter — an opening exactly at the minimum will be a tight install. Measure carefully before ordering.\u003c\/p\u003e\n\u003ch3\u003eProjection kit (optional)\u003c\/h3\u003e\n\u003cp\u003eIf the fireplace depth is less than the minimum 19 5\/8\", the optional projection kit (SBI AC01323) extends the insert 2 or 4 inches forward of the fireplace facing. With the kit installed, the depth requirement reduces to 17 5\/8\" (2\" projection) or 15 5\/8\" (4\" projection). The projection kit requires an optional backing plate (AC01322 or AC01332) to be installed first — the projection kit attaches to the backing plate, not directly to the insert. Ordered as a separate accessory.\u003c\/p\u003e\n\u003ch3\u003eFaceplate options\u003c\/h3\u003e\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eConfiguration\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eSize\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eStandard surround (included)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e35 7\/8\" × 25\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eOptional backing plate (SBI AC01322)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e29\" × 44\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eOptional backing plate (SBI AC01332)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e29\" × 50\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 14px;\"\u003eThe standard cast-iron flush-mount surround covers most masonry openings. For larger openings, an optional backing plate attaches to the back of the standard surround to extend the cover area and seal off the fireplace face. For raised-hearth installations, matching bottom backing plates (AC01321 for 44\" × 6\" or AC01333 for 50\" × 6\") are available. Selected at order if needed.\u003c\/p\u003e\n\u003ch3\u003eClearances to combustibles\u003c\/h3\u003e\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eSurface\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eMin\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eAdjacent combustible side wall\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e16\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eFaceplate to combustible side or top surround\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e9\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustible mantel shelf\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e27\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustible top surround projection\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e27\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003ePlatform \/ floor protection to ceiling\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e84\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-top: 18px;\" class=\"data-head\"\u003e\n\u003cspan\u003eSurface\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eMax thickness\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustible side surround\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustible mantel shelf projection\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e12\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 14px;\"\u003eReduced clearances are not available by means of heat shields on this insert — the figures above are the binding minimums.\u003c\/p\u003e\n\u003ch3\u003eFloor protection\u003c\/h3\u003e\n\u003cp\u003eFloor protection requirements depend on whether the existing masonry hearth is raised 5 inches or more above the surrounding combustible floor. If the hearth is raised 5 inches or more, a non-combustible floor protector with no R-value is required and must extend at least 16 inches in front of the unit in the USA, 18 inches in Canada. If the hearth is raised less than 5 inches, a non-combustible floor protector with an R-value of at least 1.00 is required and must extend at least 23 inches in front of the unit. The manual includes a thermal-resistance lookup table for common floor protection materials (brick, cement board, ceramic tile, marble) to calculate the required R-value combination.\u003c\/p\u003e\n\u003ch3\u003eChimney and liner\u003c\/h3\u003e\n\u003cp\u003eThe Destination 2.3 requires a continuous 6-inch stainless-steel chimney liner extending from the insert flue collar to the top of the chimney. The liner must conform to ULC S635 or CAN\/ULC-S640 (Canada) or UL 1777 (USA) and be rated for solid fuel. Per the manual, minimum chimney height is 12 feet. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally, subject to local code and installer verification.\u003c\/p\u003e\n\u003cp\u003eReduction of the liner diameter below 6 inches is not permitted in the USA — 6 inches is the minimum. In Canada only, a 5-inch liner is permitted if the masonry chimney exceeds 20 feet total height and the application is verified and authorized by a qualified installer. The insert is not approved for a \"positive flue connection\" to clay tile — a continuous stainless liner is required.\u003c\/p\u003e\n\u003cp\u003eIf the existing fireplace's throat damper is to remain, it must be locked open to clear the liner; otherwise the damper plate must be removed. A sheet-metal block-off plate (or, in Canada per CSA B365, mineral wool packing around the liner) is recommended at the throat to reduce cold-air backdraft into the room. An insulated liner (or pre-insulated liner with a wrap) improves draft and reduces creosote, and is required by code in some jurisdictions for clearance reasons.\u003c\/p\u003e\n\u003ch3\u003eOutside air\u003c\/h3\u003e\n\u003cp\u003eAn optional fresh-air intake kit is available for code jurisdictions requiring outside combustion air or for tight new-construction homes with mechanical ventilation. A smoke detector and carbon monoxide detector are required in the room where the insert is installed.\u003c\/p\u003e\n\u003ch3\u003eCode compliance\u003c\/h3\u003e\n\u003cp\u003eCode compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the insert is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. In Canada the CSA B365 standard applies; in the USA, ANSI NFPA 211 applies. Confirm local requirements before purchasing.\u003c\/p\u003e\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\n\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat's in the box, what you'll add\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003ch3\u003eShips with the insert\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDestination 2.3 wood insert (EB00044) with welded carbon-steel firebox, arched cast-iron glazed door, and contemporary cast-iron flush-mount surround\u003c\/li\u003e\n\u003cli\u003eHeat-activated 90 CFM blower assembly with AUTO\/MANUAL\/OFF switch, drawer-mounted for service access\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle and stainless-steel secondary-air tube assembly\u003c\/li\u003e\n\u003cli\u003eHigh-density refractory firebrick lining\u003c\/li\u003e\n\u003cli\u003eLiner starter adapter brackets and hardware\u003c\/li\u003e\n\u003cli\u003eDamper-removal warning plate (for installations where the masonry throat damper is removed)\u003c\/li\u003e\n\u003cli\u003eOwner's manual and product documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSold separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6-inch continuous stainless-steel chimney liner kit (UL 1777, CAN\/ULC-S635, or CAN\/ULC-S640) — required for installation, sized to the chimney height\u003c\/li\u003e\n\u003cli\u003eHearth extension or floor protector sized per manual specifications, with R-value of at least 1.00 if hearth is raised less than 5 inches\u003c\/li\u003e\n\u003cli\u003eOptional faceplate backing plate (SBI AC01322 or AC01332) — see \"Where it can go\" for details\u003c\/li\u003e\n\u003cli\u003eOptional bottom faceplate backing plate (AC01321 or AC01333) — for raised-hearth installations; see \"Where it can go\" for details\u003c\/li\u003e\n\u003cli\u003eOptional projection kit (SBI AC01323) — see \"Where it can go\" for details\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake kit (SBI AC01298) — for code jurisdictions requiring outside combustion air or for tight new-construction homes\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch insulated flex pipe for fresh-air intake (SBI AC02090) — UL 181 class 0 or class 1 insulated HVAC pipe\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake register with airtight damper (SBI AC01349) — closable outside-air damper; do not close while the insert is in use\u003c\/li\u003e\n\u003cli\u003eOptional rigid fire screen (SBI AC01315) — not permitted for open-door use in the United States or in Canadian provinces\/jurisdictions with particulate-emission limits; never leave the insert unattended when used with a fire screen\u003c\/li\u003e\n\u003cli\u003eOptional liner offset adapter or liner fastening system (SBI AC02006) — for installations where the chimney throat geometry requires offset connection; restricts flow somewhat and should only be used when no other option is possible and chimney height is at least 20 feet\u003c\/li\u003e\n\u003cli\u003ePin-type wood moisture meter — not optional in practice\u003c\/li\u003e\n\u003cli\u003eFlue thermometer — strongly recommended for insert installations since stove-top temperature isn't accessible\u003c\/li\u003e\n\u003cli\u003eInstallation by an authorized qualified technician (WETT, NFI, or CSIA certified) — required for warranty coverage and often required by code, permit, or insurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow it actually performs\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cp\u003eThe 75,000 BTU\/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 14,200–44,500 BTU\/hr band per the CSA B415.1-10 stack-loss method — a usable range that covers shoulder-season heating on the low end and serious cold-snap output on the high end.\u003c\/p\u003e\n\u003cp\u003eA realistic burn cycle from a packed load of well-seasoned hardwood produces a 30–45 minute warm-up, 2–3 hours of strong sustained heat once the firebox and surrounding masonry come up to temperature, then a gradual decline over the next 3–4 hours with a coal bed remaining. Total useful heat from one full pack is realistically 6–7 hours, occasionally approaching the 8-hour manufacturer maximum with dense hardwood, mild weather, and a packed coal bed.\u003c\/p\u003e\n\u003cp\u003eThe masonry around the insert acts as a thermal mass. Once the surrounding brick or stone is up to temperature, it continues radiating heat into the room well after the active fire has died down. This is one of the underappreciated benefits of an insert versus a freestanding stove — the masonry stores and releases heat on its own cycle. The first hour from a cold start is the slowest because that mass has to come up to temperature; once it's hot, response time is faster.\u003c\/p\u003e\n\u003cp\u003eThe 90 CFM heat-activated blower is what gets the heat into the room. Because most of the insert's firebox sits inside the masonry cavity, the radiant heat that would otherwise reach the room from a freestanding stove is partly absorbed by the surrounding brick. The convection jacket around the firebox captures that heat and the blower pushes it out through the bottom of the surround. With the switch in AUTO, the blower starts automatically once the insert is hot enough and stops when it cools — set the position and forget about it. With the switch in MANUAL, the blower runs continuously regardless of insert temperature.\u003c\/p\u003e\n\u003cp\u003eAllow the insert to reach operating temperature (approximately one hour from a cold start) before turning the blower to MANUAL. Per the manual, turning the blower on too early during start-up pulls heat away from the firebox and slows the build-up to clean combustion. AUTO mode handles this timing automatically.\u003c\/p\u003e\n\u003cp\u003eAir-wash glass stays largely clear during proper hot burns at moderate-to-high air settings. At low burn rates with marginally seasoned wood, the glass will tar. This is universal to non-catalytic stoves and inserts, not specific to Enerzone.\u003c\/p\u003e\n\u003cp\u003ePower-failure operation: the insert continues to burn safely without electricity — only the blower stops. Heat distribution drops noticeably without the blower because the masonry cavity absorbs most of the firebox radiation. Plan accordingly if you're buying this insert specifically as a power-outage heat source.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eTrade-offs to know\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eInsert, not a freestanding stove.\u003c\/strong\u003e The Destination 2.3 requires an existing masonry fireplace plus a full stainless-steel chimney liner — there's no other approved installation path. Buyers without a masonry fireplace should look at a freestanding equivalent (Enerzone Solution 2.3 or Osburn 2000) instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSame firebox as the Solution 2.3-I and Osburn Matrix Insert.\u003c\/strong\u003e The Destination 2.3, the Enerzone Solution 2.3-I, and the Osburn Matrix Insert share the same SBI medium-large insert performance platform — same firebox, same combustion chamber, same 20-inch log capacity, same 75,000 BTU\/hr maximum output. The differences are surround style, blower CFM, and emissions tuning. The Destination 2.3 has the contemporary flush-mount surround and a 90 CFM blower; the Solution 2.3-I has a more traditional faceplate and a stronger 144 CFM blower; the Matrix Insert has a similar contemporary look to the Destination but with the Osburn brand finish and lower-emission tuning. Choose by the look and bundling you prefer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMedium-large firebox, medium-long burn time.\u003c\/strong\u003e A 2.4 ft³ non-cat insert gives you meaningful primary-heat capability across 1,200–1,800 sq ft, with realistic 6–7 hour burn cycles. If you want true 10+ hour overnight burns, step up to a 3.0+ ft³ insert or to a catalytic stove with a real low-output mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 2,100 sq ft figure is aspirational.\u003c\/strong\u003e The most consistent owner regret across medium-large inserts is buying for the high end of the manufacturer's heating range. If you need to reliably heat more than ~1,800 sq ft as primary winter heat in a cold climate or older home, step up a firebox size — the Destination 2.7 gives meaningfully more usable heat for the same operational effort.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe blower is essential, not optional.\u003c\/strong\u003e Unlike a freestanding stove where the blower meaningfully improves heat distribution, on an insert the blower is what gets the heat into the room at all. Most of the firebox sits inside the masonry cavity, which absorbs radiant heat. The insert will run safely without the blower (useful in a power outage), but day-to-day heat into the room depends on the blower being on and working.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2.3 g\/hr emissions is mid-pack for the category.\u003c\/strong\u003e The Destination 2.3 is well within the EPA 2020 cordwood limit (2.5 g\/hr) but is not class-leading on emissions. Buyers who specifically want lower emissions for an EPA non-attainment county should compare the Osburn Matrix Insert (same platform, 1.54 g\/hr tuning) or the Destination 2.7 (1.2 g\/hr, larger firebox).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExisting fireplace dimensions are non-negotiable.\u003c\/strong\u003e The masonry opening must meet the manual's minimum dimensions (23 3\/4\" H × 28 7\/8\" W × 19 5\/8\" D). Backing plates can cover a larger opening, but they cannot compensate for an undersized one. The projection kit can extend the insert forward by 2 or 4 inches if depth is short, but not enough to fit a substantially shallow fireplace. Measure before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWood quality is not negotiable.\u003c\/strong\u003e The most common \"the insert doesn't heat\" complaint comes from owners running marginally seasoned wood. Secondary combustion works best with dry, properly seasoned fuel, ideally around 15–20% moisture. A pin-type moisture meter is the single best accessory for this insert.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContemporary, not traditional.\u003c\/strong\u003e The cast-iron flush-mount surround is intentionally clean and modern. Buyers wanting heavy decorative cast iron, louvered faceplates, or visible-grille traditional styling should look at the Solution 2.3-I (more traditional faceplate) or premium-tier alternatives.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eOperating reality\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cp\u003e\u003cstrong\u003eFirst burns.\u003c\/strong\u003e The first few fires cure the high-temperature paint and condition the internal components. Burn two or three small fires first, then build bigger, hotter fires until the paint smell is gone. The smell can be strong; ventilate the room well and avoid prolonged exposure during cure-in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLighting.\u003c\/strong\u003e The manual describes three methods: conventional (newspaper, kindling, larger pieces from bottom up), top-down (full firewood on bottom, kindling and newspaper on top, burns top down for 2+ hours), or two-parallel-logs (two split logs with newspaper between them, kindling across, log-cabin style). Top-down is the cleanest-burning method for cold starts. Whichever method you use, open the air control fully, light the paper, leave the door slightly ajar until the kindling is fully engaged, then close and latch the door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir control.\u003c\/strong\u003e Single-lever, located underneath the ash shelf. Pull the handle completely (HIGH) to open the air; push completely (LOW) to close it. Full open at light-off; gradually closed only after the load is fully engaged and stable secondary flames are established. The manual specifies closing the primary air control gradually from the time the door closes to fully closed — too fast and the fire smolders.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBlower switch positions.\u003c\/strong\u003e The 90 CFM blower assembly has a three-position switch: (1) MANUAL — runs continuously regardless of insert temperature; (2) OFF — blower stopped; (3) AUTO — blower starts when the insert is hot enough and stops when it cools down. Use AUTO for normal operation; use MANUAL only when you want continuous airflow regardless of temperature. Allow the insert to reach operating temperature before turning the blower to MANUAL from a cold start.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReload cadence.\u003c\/strong\u003e 3–4 hours between reloads in active heating use; up to 7 hours for a final overnight pack with the air shut hard. Rake remaining charcoal toward the front of the firebox before loading — this concentrates the coals near where most of the combustion air enters and helps ignite the new load. Load three logs east-west on the coal bed with 1 inch of air space from the rear firebrick, then two more logs angled slightly on top. Open the air for a minute or two before opening the door, open the door slowly to avoid smoke rollout, load, close the door, and run the air open until the load is fully engaged before reducing gradually. Do not elevate the fire by using a grate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBurn in cycles, not single-log feeds.\u003c\/strong\u003e The manual is explicit: do not attempt to produce steady heat output by placing a single log on the fire at regular intervals. Always place at least three (preferably more) pieces on the fire at a time so the heat radiated from one piece helps ignite the pieces next to it. Each load should provide several hours of heating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsh management.\u003c\/strong\u003e Empty ash every 2–3 days during full-time heating. The best time to remove ash is after an overnight fire when the insert is relatively cool but there is still some chimney draft to draw ash dust into the insert rather than into the room. Always dispose of ash in a tightly covered metal container on a non-combustible surface, well away from combustible materials — ash retains hot embers for days. Never store ashes indoors, in a non-metallic container, or on a wooden deck.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlass cleaning.\u003c\/strong\u003e Damp newspaper dipped in cold ash, or a dedicated ceramic-glass cleaner. Daily wipe during low-burn weather; weekly during high-burn. Black streaks at the lower edge mean wet wood; black uniformly across the glass means burns are running too cool. Brown stains at the lower corners mean smoky combustion. Do not clean the glass when the insert is hot, and do not strike or slam the glass door shut.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoor and glass gaskets.\u003c\/strong\u003e Per the manual, the door gasket needs replacement when the paper-strip test fails: close the door on a strip of paper and try to pull it out; firm resistance means the gasket is sealing, easy pull means it's time to replace. Test all the way around the door, not just at the latch. The latch mechanism is adjustable via the door pressure plate bolts. Plan on every 3–5 seasons in regular use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnnual chimney sweep.\u003c\/strong\u003e Per the manual, the chimney liner should be cleaned and inspected at least once each year. Inspect every two months during the heating season until you know your creosote-formation rate; monthly is safer for new burners. If buildup reaches 1\/8 inch, sweep immediately. The baffle lifts out for sweep access. Insert installations make sweeping more involved than freestanding stoves — many owners hire a CSIA-certified sweep rather than doing it themselves.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWood seasoning.\u003c\/strong\u003e Hardwood needs 12–24 months split, stacked off the ground, top-covered, with sun and wind on the sides. Don't trust supplier \"seasoned\" claims — use a pin-type moisture meter, split a piece in half, measure the fresh face. Manual target: 15–20% moisture. Wood above 25% will smolder, soot the glass, line the chimney with creosote, and undercut every published efficiency and emissions number on this page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBlower maintenance.\u003c\/strong\u003e Keep the blower intake and fins free of dust. The drawer-mounted assembly slides out for service access — vacuum dust accumulation annually. Do not oil the blower unless the blower manual specifically calls for lubrication. Replacement blowers and related service parts are available through Enerzone\/SBI dealers and parts channels if needed years out.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat never to burn.\u003c\/strong\u003e Per the manual and EPA fuel rules: no coal, garbage, yard waste, materials containing rubber or plastic, waste petroleum products, paint or paint thinners, asphalt products, painted or pressure-treated wood, railroad ties, manure or animal remains, plywood, particle board, paper products, asbestos materials, construction or demolition debris, salt-water driftwood, or unseasoned wood. This does not prohibit normal fire starters made from paper, cardboard, sawdust, wax, or similar substances when used only to start a fire. Burning prohibited materials destroys the firebox, voids the warranty, and releases toxic compounds into your home and the chimney. Do not burn manufactured logs made of wax-impregnated sawdust or logs with chemical additives; 100% compressed-sawdust logs can be used but never more than two at a time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWarranty and service\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cp\u003eThe Enerzone limited lifetime warranty applies to the original retail purchaser only and is non-transferable. The warranty applies to normal residential use only. Proof of purchase (dated bill of sale), model name, and serial number are required for any warranty claim. Online registration is recommended at enerzone-intl.com but not required if a dated invoice is retained.\u003c\/p\u003e\n\u003ch3\u003eCoverage by component\u003c\/h3\u003e\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eComponent\u003c\/span\u003e\u003cspan\u003eParts\u003c\/span\u003e\u003cspan\u003eLabor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustion chamber welds, cast-iron door frame\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCeramic glass, plating manufacturing defects\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSurrounds, heat shields, trims, C-Cast baffle, secondary air tubes\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e7 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eHandle assembly, glass retainers, air control mechanism\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e3 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eRemovable carbon-steel firebox components\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eBlower, heat sensors, switches, wiring, electronics\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e2 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003ePaint (peeling), gaskets, insulation, ceramic fiber blankets, and other options\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eReplacement parts under warranty\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e90 d\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin-top: 14px;\"\u003eA one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.\u003c\/p\u003e\n\u003cp\u003eWarranty claims are made through your Enerzone dealer and remain subject to SBI\/Enerzone inspection, approval, and the current written warranty. Kaminos is the retailer for this insert and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer.\u003c\/p\u003e\n\u003cp class=\"warranty-note\"\u003eEnerzone may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.\u003c\/p\u003e\n\u003cp class=\"warranty-note\"\u003eCoverage details can change by component and warranty revision; the current Enerzone warranty controls.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCompare with\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eEnerzone Solution 2.3-I Wood Insert\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSame SBI medium-large insert performance platform — same firebox, same combustion chamber, same 20\" log capacity, same 75,000 BTU\/hr maximum, same warranty schedule, same EPA 2020 certification class. The Solution 2.3-I uses a more traditional faceplate with keystone styling (available in 29\" × 44\" or 32\" × 50\" sizes, plus cuttable options for irregular fireplace openings) and ships with a stronger 144 CFM blower vs the Destination's 90 CFM. Choose the Solution 2.3-I if you want a traditional aesthetic and more aggressive heat distribution; choose the Destination 2.3 for the contemporary flush-mount cast-iron look.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eOsburn Matrix Wood Insert\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSame SBI medium-large insert platform with similar contemporary cast-iron flush-mount styling, but in the Osburn brand. The Matrix Insert has a meaningfully lower published emissions rate (1.54 g\/hr vs 2.3 g\/hr on the Destination) and a slightly larger 19 5\/8\" × 11 7\/8\" glass surface. Same 90 CFM heat-activated blower, same firebox performance. Choose the Matrix if you want the Osburn brand and class-leading emissions; choose the Destination 2.3 if you prefer the Enerzone brand and pricing.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eEnerzone Destination 2.7 Wood Insert\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eStep up in the Destination line. 80,000 BTU\/hr maximum output, 1.2 g\/hr emissions (substantially lower), eloquent cast-iron faceplate with a distinctive louver and larger glass surface. Choose the Destination 2.7 if you need more heat output, want class-leading emissions, and the larger faceplate works in your space; choose the Destination 2.3 for a more compact contemporary surround at a lower price point.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003ePacific Energy Summit Insert\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003ePremium cross-brand competitor in the medium-large insert class. Sealed-firebox technology, premium build, higher price. The most-mentioned cross-shop on hearth-enthusiast forums for buyers comparing mid-to-large wood inserts. Higher price; longer real-world burn potential.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp class=\"pull\"\u003eThe Destination 2.3 is the contemporary cast-iron wood insert in the Enerzone line. Built to turn an existing masonry fireplace into a serious heat source, with 20-inch logs, an 8-hour burn cycle, and the 90 CFM heat-activated blower included as standard. Measure the opening, install it right, burn good wood, and it carries you through winter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Enerzone","offers":[{"title":"Default Title","offer_id":50192706175169,"sku":"EB00044","price":3949.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/3854\/4065\/files\/Enerzone_Destination_2.3_Wood_Insert_Kaminos.webp?v=1778193129","url":"https:\/\/kaminos.com\/products\/enerzone-destination-2-3-wood-insert","provider":"Kaminos","version":"1.0","type":"link"}