{"product_id":"enerzone-solution-2-3-wood-stove","title":"Enerzone Solution 2.3 Wood Stove","description":"\u003cdiv style=\"font-family: 'Inter', -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #231F20; line-height: 1.55; width: 100%; max-width: 100%; box-sizing: border-box; margin: 0; padding: 0; font-size: 16px; overflow-wrap: break-word; word-wrap: break-word; word-break: normal;\"\u003e\n\n\u003cstyle\u003e\n  .km-desc, .km-desc * { box-sizing: border-box; max-width: 100%; }\n  .km-desc { width: 100%; }\n  .km-desc p { margin: 0 0 14px; }\n  .km-desc h3 { font-size: 11px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: 600; color: #9B774D; margin: 22px 0 10px; }\n  .km-desc .spec-list { margin: 12px 0 0; }\n  .km-desc .spec-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .spec-row:first-child { border-top: 1px solid rgba(75,72,75,0.35); padding-top: 14px; }\n  .km-desc .spec-label { font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; margin-bottom: 6px; }\n  .km-desc .spec-value { font-weight: 600; font-size: 15px; color: #231F20; margin-bottom: 6px; line-height: 1.35; }\n  .km-desc .spec-meaning { color: #4B484B; font-size: 13px; line-height: 1.55; }\n  @media (min-width: 720px) {\n    .km-desc .spec-row { display: grid; grid-template-columns: 38% 30% 1fr; gap: 16px; align-items: start; padding: 12px 0; }\n    .km-desc .spec-label { margin-bottom: 0; align-self: center; }\n    .km-desc .spec-value { margin-bottom: 0; font-size: 14px; align-self: center; }\n    .km-desc .spec-meaning { font-size: 13px; }\n    .km-desc .spec-row:first-child { padding-top: 12px; }\n  }\n  .km-desc .data-row { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding: 12px 0; border-bottom: 1px solid rgba(75,72,75,0.12); align-items: baseline; font-size: 13px; }\n  .km-desc .data-head + .data-row { border-top: 1px solid rgba(75,72,75,0.35); }\n  .km-desc .data-row .data-label { color: #4B484B; line-height: 1.4; }\n  .km-desc .data-row .data-val { font-weight: 600; color: #231F20; text-align: right; min-width: 56px; }\n  .km-desc .data-head { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding-bottom: 8px; font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; }\n  .km-desc .data-head span:nth-child(2), .km-desc .data-head span:nth-child(3) { text-align: right; min-width: 56px; }\n  .km-desc ul { list-style: none; padding: 0; margin: 10px 0 14px; }\n  .km-desc ul li { padding: 4px 0 4px 18px; position: relative; line-height: 1.55; }\n  .km-desc ul li:before { content: \"—\"; position: absolute; left: 0; color: #9B774D; font-weight: 500; }\n  .km-desc .compare-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .compare-row:last-child { border-bottom: 0; }\n  .km-desc .compare-name { font-weight: 600; color: #231F20; display: inline-block; padding-bottom: 1px; }\n  .km-desc .compare-orient { color: #4B484B; margin-top: 4px; font-size: 13px; line-height: 1.5; }\n  .km-desc .pull { font-style: italic; font-size: clamp(16px, 4.2vw, 22px); line-height: 1.4; color: #231F20; border-left: 2px solid #9B774D; padding: 0 0 0 16px; margin: 32px 0 16px; }\n  .km-desc .lede { font-size: clamp(16px, 4vw, 22px); line-height: 1.4; letter-spacing: -0.2px; font-weight: 400; color: #231F20; margin: 0 0 24px; }\n  .km-desc .warranty-note { font-size: 12px; color: #4B484B; font-style: italic; margin-top: 14px; }\n  .km-desc details { border-top: 1px solid rgba(75,72,75,0.18); margin: 0; padding: 0; }\n  .km-desc details:last-of-type { border-bottom: 1px solid rgba(75,72,75,0.18); }\n  .km-desc details \u003e summary { list-style: none; cursor: pointer; padding: 18px 32px 18px 0; position: relative; font-size: clamp(16px, 4.2vw, 20px); line-height: 1.3; font-weight: 500; color: #231F20; letter-spacing: -0.2px; }\n  .km-desc details \u003e summary::-webkit-details-marker { display: none; }\n  .km-desc details \u003e summary::after { content: \"+\"; position: absolute; right: 4px; top: 50%; transform: translateY(-50%); font-size: 22px; font-weight: 300; color: #9B774D; line-height: 1; }\n  .km-desc details[open] \u003e summary::after { content: \"−\"; }\n  .km-desc details \u003e summary:focus-visible { outline: 2px solid #9B774D; outline-offset: 4px; }\n  .km-desc details \u003e .acc-body { padding: 0 0 28px 0; }\n\u003c\/style\u003e\n\n\u003cdiv class=\"km-desc\"\u003e\n\n\u003cp class=\"lede\"\u003eA 2.4 ft³ non-catalytic medium-large freestanding wood stove — the larger step-up in the Enerzone Solution line. EPA 2020 cordwood certified at 72% HHV efficiency and 2.3 g\/hr emissions, with a 20-inch maximum east-west log capacity, up to 2,100 sq ft of heating area, an 8-hour maximum burn time, mobile-home approval, 75,000 BTU\/hr maximum output, an optional 130 CFM variable-speed blower, and a required base selection at order (three leg styles in Black or Brushed Nickel, or a pedestal).\u003c\/p\u003e\n\n\u003cdetails open\u003e\n\u003csummary\u003eWho this is for\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003ch3\u003eRight buyer\u003c\/h3\u003e\n\u003cp\u003eOwners of medium-to-larger homes, well-insulated open-plan two-story spaces, or one stove serving as primary winter heat across 1,200–1,800 sq ft of conditioned space, with reasonable insulation and access to seasoned hardwood at 15–20% moisture content. Mobile-home and manufactured-home owners — this stove is certified for mobile-home installation with the required fresh-air intake kit and insulated intake pipe.\u003c\/p\u003e\n\u003cp\u003eBuyers stepping up from the medium-stove platform (Solution 1.7) who want a meaningful firebox jump, longer 20-inch logs, and longer burn cycles. The Solution 2.3 covers heating areas from 500 sq ft on the low end up to 2,100 sq ft on the manufacturer's high end, with a tested output band of 14,200–44,500 BTU\/hr — a usable range for both shoulder seasons and cold-snap loads.\u003c\/p\u003e\n\u003cp\u003eBuyers who want east-west loading and the wider 17 1\/2-inch door opening that comes with it. The Solution 2.3 is built around a wider-than-it-is-deep firebox; logs go in across the width, sides visible from the door. Per the manual, the firebox also accepts north-south loading thanks to the 16 1\/2\" depth — useful for packed overnight loads.\u003c\/p\u003e\n\u003cp\u003eBuyers who want configurable styling. The Solution 2.3 ships with a choice of seven base configurations: three leg styles (round, traditional, flared) in either Black or Brushed Nickel, or a pedestal — letting the stove sit anywhere from low-slung to elevated depending on the room. The arched cast-iron door and engraved-groove side panels deliver a refined-but-not-ornate look.\u003c\/p\u003e\n\n\u003ch3\u003eWrong buyer\u003c\/h3\u003e\n\u003cp\u003eNot for buyers heating under 1,000 sq ft. The Solution 2.3 is meaningfully larger than the Solution 1.4 or 1.7; in a small room it will overheat at almost any meaningful burn rate. If you're heating a small space, look at the smaller Solution 1.4 or 1.7 instead.\u003c\/p\u003e\n\u003cp\u003eNot for buyers expecting 10+ hour overnight burns. The 8-hour manufacturer maximum is achievable on a packed load of dense hardwood with the air shut down hard, but useful heat from a packed load is realistically 6–7 hours. For longer burns, step up to a 3.0+ ft³ firebox or to a catalytic stove with a real low-output mode.\u003c\/p\u003e\n\u003cp\u003eNot for buyers wanting heavy decorative cast-iron styling. The Solution 2.3 has clean lines and refined Enerzone detailing, but it is not an ornate cast-iron showpiece. Buyers who want furniture-grade cast iron should look at premium-tier alternatives.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eAt a glance\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cdiv class=\"spec-list\"\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion technology\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eNon-catalytic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eSecondary-air tubes reignite smoke gases. No catalyst to replace; one air-control lever; simpler operation than a cat stove but shorter low-and-slow burn times.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFirebox volume\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e2.4 ft³ overall \/ 1.95 ft³ EPA\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manufacturer spec. Medium-large firebox sized for zone heating across 500–2,100 sq ft. The overall figure includes a buffer zone above the EPA loading line; the 1.95 ft³ figure is the usable loading volume used during EPA emissions certification.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum heat output\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e75,000 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePeak output on dry cordwood, transient. Sustained output across a burn cycle is substantially lower.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eTested output range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e14,200–44,500 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer CSA B415.1-10 stack-loss method. The realistic operating band buyers should plan around.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eHeating range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e500–2,100 sq ft\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer's stated range. Real-world comfort sizing for primary heat is roughly 1,200–1,800 sq ft in moderate climates and lower in cold climates or older homes — depends on insulation, layout, climate, ceiling height, fuel quality, and installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAverage efficiency\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e72% HHV \/ 77% LHV\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e79% optimum overall efficiency at low burn rate; 76% optimum heat-transfer efficiency. HHV is the federal standard. Government incentives may apply by jurisdiction and installation date.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eParticulate emissions\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e2.3 g\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eEPA 2020 cordwood certified (limit is 2.5 g\/hr). Tested by an independent accredited laboratory.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAverage CO emissions\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e69 g\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eAverage carbon monoxide emissions per CSA B415.1-10 stack-loss method.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum burn time\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eUp to 8 hours\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer maximum at the lowest air setting. Useful heat through a burn cycle is realistically 6–7 hours.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eRecommended log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e16 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Most firewood suppliers cut to this length.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e20 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e4-inch margin over the recommended length — meaningful for buyers with access to longer-cut firewood. Logs load across the width of the firebox, sides visible from the door.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eCarbon steel, cast-iron door\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eWelded carbon-steel firebox (3\/16\" body, 3\/8\" top) with an arched cast-iron door, engraved-groove side panels, and the refined Enerzone finish. Lifetime warranty on the combustion-chamber welds.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBase configuration\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eSeven options, required\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eThree leg styles (traditional, round, flared), each in Black or Brushed Nickel finish, or a pedestal in Black. Configured at order; not field-swappable. Each base includes a built-in ash drawer.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBaffle\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eC-Cast\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eRigid aluminosilicate fiber baffle rated above 2,000 °F.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eGlass\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e16 5\/8\" × 10 5\/8\", ceramic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eViewable glass surface, per Enerzone's official spec. Ceramic glass with air-wash, tested to 1,400 °F. Replacement glass must match manufacturer specifications.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBlower\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eOptional, 130 CFM variable speed\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eSold separately. 130 CFM blower with variable speed control and thermodisc heat sensor for automatic on\/off based on stove temperature. Without the blower, heat distribution relies on radiant heat and natural convection; there is no forced-air circulation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAirmate\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eOptional\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eOptional top-mounted accessory that accumulates heat and increases airflow off the stove top. Sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFlue connection\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e6 in\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eTop of the unit. Chimney must be 6 in interior diameter. Type of chimney: CAN\/ULC S629 or UL 103 HT (2100 °F). Sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMinimum chimney height\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e12 ft\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manufacturer spec, subject to installer verification, certification label, draft conditions, and local code.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion chamber\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e21\" W × 16 1\/2\" D × 11 7\/8\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eInside firebox dimensions per manufacturer spec. Wider than deep; the 16 1\/2\" depth is generous enough to accept N-S loading as well as the default E-W loading.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eDoor opening\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e17 1\/2\" W × 9\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eLoading door opening. The wide door accommodates 20-inch logs loaded east-west.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eOverall dimensions\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e27\" W × 26 1\/2\" D × 32 3\/4\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eOverall appliance dimensions per manufacturer spec.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eShipping weight\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e402 lb\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePlan for three-person handling. Remove loose internal components as appropriate during installation to reduce handling weight.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMobile home approved\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eYes\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eMobile-home and manufactured-home installations are supported with the required fresh-air intake kit and an insulated intake pipe (HVAC type, ULC S110 or UL 181 class 0\/1). Both are sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCountry of origin\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eMade in Canada\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufactured by Stove Builder International (SBI) in Saint-Augustin-de-Desmaures, Quebec.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhere it can go\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe Solution 2.3 is approved for installation in residential homes, cabins, sunrooms, and mobile or manufactured homes (with the required fresh-air intake kit and insulated intake pipe). It is not approved for installation in factory-built (prefab) metal fireplaces or in any outdoor or unconditioned space.\u003c\/p\u003e\n\n\u003ch3\u003eClearances to combustibles — USA\u003c\/h3\u003e\n\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eSurface\u003c\/span\u003e\u003cspan\u003eSingle-wall pipe\u003c\/span\u003e\u003cspan\u003eDouble-wall pipe\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eBack wall to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e11\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e6\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCorner to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e10\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e7\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSide wall to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e16\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e16\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eTop (platform to ceiling)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e84\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e84\"\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eClearances to combustibles — Canada\u003c\/h3\u003e\n\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eSurface\u003c\/span\u003e\u003cspan\u003eSingle-wall pipe\u003c\/span\u003e\u003cspan\u003eDouble-wall pipe\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eBack wall to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e14 1\/2\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e6\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCorner to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e10\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e7\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSide wall to unit\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e17\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e17\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eTop (platform to ceiling)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e84\"\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e84\"\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top: 14px;\"\u003eThe certification label on the back of the stove always overrides clearance figures published in any other media. Confirm the binding clearance figures with your installer before purchase. The install manual specifies additional reduced clearances available with approved wall heat-shield construction; review with your installer.\u003c\/p\u003e\n\n\u003ch3\u003eFloor protection\u003c\/h3\u003e\n\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eDirection (from door opening)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eMin\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eFront extension (USA)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e16\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eFront extension (Canada)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e18\"\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSide extension (each side)\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e8\"\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top: 14px;\"\u003eFor the Solution 2.3, the manual specifies \u003cstrong\u003eno R-factor required\u003c\/strong\u003e for floor protection — only a continuous, non-combustible material. Approved materials include steel of at least 0.015\" thickness, ceramic tiles sealed together with grout (over a continuous non-combustible sheet beneath), cement board, brick, or any other approved or listed material suited for floor protection. Tile alone is not sufficient — a continuous non-combustible sheet beneath the tile is required. No floor protection is required if the stove is installed on a non-combustible floor (concrete slab, for example).\u003c\/p\u003e\n\n\u003ch3\u003eChimney and venting\u003c\/h3\u003e\n\u003cp\u003eThe Solution 2.3 requires a 6-inch chimney flue system. New factory-built chimney systems must comply with UL 103 HT (USA) or ULC S629 (Canada) and be suitable for solid fuel. The stove may also be connected to a code-compliant masonry chimney, provided the chimney has either a clay liner or a suitably listed stainless-steel liner at 6-inch diameter and the application is verified by a qualified installer.\u003c\/p\u003e\n\n\u003cp\u003eThe minimum chimney height is 12 feet, subject to installer verification, certification label, draft conditions, and local code. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally.\u003c\/p\u003e\n\n\u003cp\u003eFor mobile-home installations, single-wall pipe is strictly forbidden — only double-wall pipe is permitted, and a fresh-air intake kit with insulated intake pipe is required. The fresh-air intake pipe (HVAC type) must meet ULC S110 or UL 181 class 0 or class 1.\u003c\/p\u003e\n\n\u003ch3\u003eOutside air\u003c\/h3\u003e\n\u003cp\u003eAn optional fresh-air intake kit is available for code jurisdictions requiring outside combustion air, for tight new-construction homes with mechanical ventilation, and is required for mobile-home installations. Two different kits are offered depending on base configuration — one for legs versions and one for the pedestal version. Confirm the correct kit for the chosen base. A smoke detector and carbon monoxide detector are required in the room where the stove is installed.\u003c\/p\u003e\n\n\u003ch3\u003eCode compliance\u003c\/h3\u003e\n\u003cp\u003eCode compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the stove is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. Confirm local requirements before purchasing — particularly in EPA non-attainment counties and in HOA jurisdictions where new wood-burning installs may be restricted.\u003c\/p\u003e\n\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\n\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat's in the box, what you'll add\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003ch3\u003eShips with the stove\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSolution 2.3 wood stove with welded carbon-steel firebox and arched cast-iron glazed door\u003c\/li\u003e\n\u003cli\u003eConfigured at order with required base selection — three leg styles (traditional, round, flared), each in Black or Brushed Nickel finish, or a pedestal in Black; each base includes a built-in ash drawer\u003c\/li\u003e\n\u003cli\u003eEngraved-groove side panels with nickel U-shaped decorative accents\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle and stainless-steel secondary-air tube assembly\u003c\/li\u003e\n\u003cli\u003eHigh-density refractory firebrick lining\u003c\/li\u003e\n\u003cli\u003eTop air deflector and rear heat shield\u003c\/li\u003e\n\u003cli\u003eOwner's manual and product documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSold separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCode-compliant 6-inch chimney system — listed factory-built chimney for new installations, or an approved masonry chimney\/liner configuration where permitted by code and verified by the installer\/AHJ; required venting components are sold separately\u003c\/li\u003e\n\u003cli\u003eSingle-wall or double-wall pipe connector between the stove and chimney — double-wall is required for mobile-home installations and reduces clearance requirements\u003c\/li\u003e\n\u003cli\u003eHearth pad or floor protection sized to manual specifications, with continuous non-combustible sheet beneath any tile\u003c\/li\u003e\n\u003cli\u003eOptional 130 CFM blower with variable speed control (SBI AC01000) — includes thermodisc heat sensor for automatic on\/off; adds forced-air circulation to improve heat distribution; without it, heat moves by radiation and natural convection only\u003c\/li\u003e\n\u003cli\u003eOptional Airmate accessory (SBI AC01197) — top-mounted heat-accumulator that increases airflow off the stove top\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake kit for wood stove on legs (SBI AC01211) — required for mobile-home installations with leg base configurations\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake kit for wood stove on pedestal (SBI AC01336) — required for mobile-home installations with pedestal base configuration\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch × 4' insulated flex pipe for fresh-air intake (SBI AC02090) — required for mobile-home installations\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake register with airtight damper (SBI AC01349) — closable outside-air damper for installations where local code, airtight-home design, or owner preference calls for one; do not close while the stove is in use\u003c\/li\u003e\n\u003cli\u003eOptional rigid fire screen (SBI AC01315) — for occasional attended fire viewing only where permitted by local code and only when used exactly as instructed in the fire screen manual; never leave the stove unattended when used with a fire screen. Open-door operation with a fire screen is prohibited in the United States and in Canadian provinces with particulate emission limits; never permitted in a mobile home\u003c\/li\u003e\n\u003cli\u003eOptional black steel hearth pad 46 3\/4\" × 54\" (SBI AC02788) — pre-sized to the Solution 2.3 footprint\u003c\/li\u003e\n\u003cli\u003eOptional black steel hearth pad 60\" corner (SBI AC02790) — for corner installations\u003c\/li\u003e\n\u003cli\u003eOptional tempered glass hearth pad 10 mm, 54\" × 46 3\/4\" (SBI AC02703) or tinted version (SBI AC02758) — for a polished finished hearth surface\u003c\/li\u003e\n\u003cli\u003ePin-type wood moisture meter (SBI AC07835) — not optional in practice\u003c\/li\u003e\n\u003cli\u003eStove-top or flue thermometer — strongly recommended; not optional in practice\u003c\/li\u003e\n\u003cli\u003eInstallation by an authorized qualified technician (WETT, NFI, or CSIA certified) — required for warranty coverage and often required by code, permit, or insurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eHow it actually performs\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe 75,000 BTU\/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 14,200–44,500 BTU\/hr band per the CSA B415.1-10 stack-loss method — a usable range that covers shoulder-season heating on the low end and serious cold-snap output on the high end.\u003c\/p\u003e\n\n\u003cp\u003eA realistic burn cycle from a packed load of well-seasoned hardwood produces a fast 30–45 minute warm-up, 2–3 hours of strong sustained heat, then a gradual decline over the next 3–4 hours with a coal bed remaining. Total useful heat from one full pack is realistically 6–7 hours, occasionally approaching the 8-hour manufacturer maximum with dense hardwood, mild weather, and a packed coal bed. Reload onto coals when heat output falls off and the cycle restarts.\u003c\/p\u003e\n\n\u003cp\u003eThe 20-inch maximum log capacity is the meaningful differentiator vs the smaller Solution 1.7 (18 in). Most firewood suppliers cut to 16 inches as standard, but 20-inch capacity gives real margin — a buyer with access to longer-cut wood gets four extra inches of fuel per log without juggling. East-west loading is the default; the firebox depth of 16 1\/2\" also accepts north-south loading for packed overnight cycles per the manual.\u003c\/p\u003e\n\n\u003cp\u003eThe 130 CFM optional blower is a meaningful step up from the smaller stoves in the catalog. With the blower installed, the variable-speed control lets you dial CFM up or down, and the thermodisc senses stove temperature and runs the blower automatically when the stove is hot. Without the blower, heat distribution relies on radiant heat and natural convection; the back heat shield helps push heat off the rear of the stove into the room. For one-room or single-zone use, radiant and natural convection are often enough. For distribution into adjacent rooms or open-plan spaces, the blower meaningfully helps.\u003c\/p\u003e\n\n\u003cp\u003eAir-wash glass stays largely clear during proper hot burns at moderate-to-high air settings. At low burn rates with marginally seasoned wood, the glass will tar. This is universal to non-catalytic stoves, not specific to Enerzone.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eTrade-offs to know\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSame platform as the Osburn 2000.\u003c\/strong\u003e The Solution 2.3 and the Osburn 2000 share the same SBI medium-large stove performance platform — same firebox, same combustion-chamber dimensions, same 20-inch log capacity, same 75,000 BTU\/hr maximum output. The Osburn 2000 adds the Osburn brand finish, a required door overlay choice (Black or Brushed Nickel), and the Osburn dealer\/parts network positioning. Choose the Solution 2.3 for the Enerzone price point and seven base configurations without the required door overlay step; choose the Osburn 2000 if you want the Osburn brand and the additional overlay finish.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMedium-large firebox, medium-long burn time.\u003c\/strong\u003e A 2.4 ft³ non-cat stove gives you meaningful primary-heat capability across 1,200–1,800 sq ft, with realistic 6–7 hour burn cycles. If you want true 10+ hour overnight burns or 2,500+ sq ft primary heating, step up to a 3.0+ ft³ firebox or to a catalytic stove with a real low-output mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe 2,100 sq ft figure is aspirational.\u003c\/strong\u003e The most consistent owner regret across medium-large stoves is buying for the high end of the manufacturer's heating range. If you need to reliably heat more than ~1,800 sq ft as primary winter heat in a cold climate or older home, step up a firebox size — the Solution 3.5 or equivalent gives meaningfully more usable heat for the same operational effort.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBase configuration is a one-time decision.\u003c\/strong\u003e Seven base configurations means the stove can fit many room layouts and aesthetics, but the base is configured at order, not field-swappable. Choose the configuration that matches the room you're putting it in — measure the desired height and confirm the look before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBlower is not included.\u003c\/strong\u003e Unlike inserts in the catalog, the Solution 2.3 ships without a blower; one must be ordered separately if you want forced-air heat distribution. For a stove sized to do real primary heat across larger spaces, the 130 CFM variable-speed blower is a near-essential add — plan for the line item.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e402 lb shipping weight.\u003c\/strong\u003e This is a meaningfully heavy stove. Plan for three-person handling at delivery and installation; the curb-to-room move is not a one-person job.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWood quality is not negotiable.\u003c\/strong\u003e The most common \"the stove doesn't heat\" complaint comes from owners running marginally seasoned wood. Secondary combustion works best with dry, properly seasoned fuel, ideally around 15–20% moisture. A pin-type moisture meter is the single best accessory for this stove.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGlass blackens at low burn rates.\u003c\/strong\u003e Universal to non-cat stoves. Daily hot cleanup burns and tolerance for a periodic wipe are part of operating this stove. Owners chasing always-clear glass on long, slow burns should look at catalytic technology.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRefined but not ornate.\u003c\/strong\u003e The Solution 2.3 has clean modern lines, an arched cast-iron door, engraved-groove side panels with nickel U-shaped decorative accents, and a choice of leg styles. It is refined but functional, not heavy decorative cast iron. Buyers wanting furniture-grade cast-iron styling should look at premium-tier alternatives.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eOperating reality\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eFirst burns.\u003c\/strong\u003e The first few fires cure the high-temperature paint and condition the internal components. Burn two or three small fires first, then build bigger, hotter fires until the paint smell is gone. The smell can be strong; ventilate the room well and avoid prolonged exposure during cure-in.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLighting.\u003c\/strong\u003e Open the air control fully and build a small, hot kindling fire. The manual's EPA loading sequence uses eight small (2\"×2\") pieces criss-crossed at the greatest possible angle on the firebox floor, kindling on top in three layers, then five sheets of newspaper tied in a knot on top. Light the paper, leave the door ajar at 90° until the kindling is fully engaged, then close the door. In normal use, the goal is the same: establish draft quickly, get the firebox hot, then close the door once the fire is stable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAir control.\u003c\/strong\u003e Single-lever, located underneath the ash shelf. Push the handle completely to the left for HIGH (open); push completely to the right for LOW (closed). Full open at light-off; gradually closed only after the load is fully engaged and stable secondary flames are established. The manual specifies closing the primary air control gradually from the time the door closes to fully closed — too fast and the fire smolders.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eReload cadence.\u003c\/strong\u003e 3–4 hours between reloads in active heating use; up to 7 hours for a final overnight pack with the air shut hard. For loading, follow the principle the manual describes for EPA testing: three logs on the coal bed in east-west orientation with one inch of air space from the rear firebrick, two more logs on top angled slightly. Open the air for a minute or two before opening the door, open the door slowly to avoid smoke rollout, load onto the coal bed, close the door, and run the air open until the load is fully engaged before reducing the air gradually. Do not elevate the fire by using a grate.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAsh management.\u003c\/strong\u003e The Solution 2.3 has a built-in ash drawer system (included with each base configuration) — the ash plug in the firebox floor opens to drop ash into the drawer below. Per the manual, empty every 2–3 days during full-time heating. Always dispose of ash in a tightly covered metal container on a non-combustible surface, well away from combustible materials — ash retains hot embers for days.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGlass cleaning.\u003c\/strong\u003e Damp newspaper dipped in cold ash, or a dedicated ceramic-glass cleaner. Daily wipe during low-burn weather; weekly during high-burn. Black streaks at the lower edge mean wet wood; black uniformly across the glass means burns are running too cool. Do not clean the glass when the stove is hot, and do not strike or slam the glass door shut.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoor and glass gaskets.\u003c\/strong\u003e Per the manual, the door gasket needs replacement when the paper-strip test fails: close the door on a strip of paper and try to pull it out; firm resistance means the gasket is sealing, easy pull means it's time to replace. Test all the way around the door, not just at the latch. The latch mechanism is also adjustable — turn the handle one counterclockwise turn (after removing the split pin with pliers) to increase pressure. Replacement is a 30-minute job. Plan on every 3–5 seasons in regular use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAnnual chimney sweep.\u003c\/strong\u003e Per the manual, the chimney should be cleaned and inspected at least once each year. Inspect every two months during the heating season until you know your creosote-formation rate; monthly is safer for new burners. If buildup reaches 1\/8 inch, sweep immediately. The baffle and secondary tubes lift out for sweep access.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWood seasoning.\u003c\/strong\u003e Hardwood needs 12–24 months split, stacked off the ground, top-covered, with sun and wind on the sides. Don't trust supplier \"seasoned\" claims — use a pin-type moisture meter, split a piece in half, measure the fresh face. Manual target: 15–20% moisture. Wood above 25% will smolder, soot the glass, line the chimney with creosote, and undercut every published efficiency and emissions number on this page.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBlower maintenance (if installed).\u003c\/strong\u003e Keep the blower intake and fins free of dust and follow the blower kit instructions for service. Do not oil the blower unless the blower manual specifically calls for lubrication. Replacement blowers and related service parts are available through Enerzone\/SBI dealers and parts channels if needed years out.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat never to burn.\u003c\/strong\u003e Per the manual and EPA fuel rules: no coal, garbage, yard waste, materials containing rubber or plastic, waste petroleum products, paint or paint thinners, asphalt products, painted or pressure-treated wood, railroad ties, manure or animal remains, plywood, particle board, paper products, asbestos materials, construction or demolition debris, salt-water driftwood, or unseasoned wood. This does not prohibit normal fire starters made from paper, cardboard, sawdust, wax, or similar substances when used only to start a fire. Burning prohibited materials destroys the firebox, voids the warranty, and releases toxic compounds into your home and the chimney.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWarranty and service\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe Enerzone limited lifetime warranty applies to the original retail purchaser only and is non-transferable. The warranty applies to normal residential use only. Proof of purchase (dated bill of sale), model name, and serial number are required for any warranty claim. Online registration is recommended at enerzone-intl.com but not required if a dated invoice is retained.\u003c\/p\u003e\n\n\u003ch3\u003eCoverage by component\u003c\/h3\u003e\n\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eComponent\u003c\/span\u003e\u003cspan\u003eParts\u003c\/span\u003e\u003cspan\u003eLabor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustion chamber welds, cast-iron door frame\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCeramic glass, plating manufacturing defects, convector airmate\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSurrounds, heat shields, ash drawer, steel legs, pedestal, trims, C-Cast baffle, secondary air tubes\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e7 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eHandle assembly, glass retainers, air control mechanism\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e3 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eRemovable carbon-steel firebox components\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eOptional blower, heat sensors, switches, rheostat, wiring, electronics\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e2 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003ePaint (peeling), gaskets, insulation, ceramic fiber blankets, and other options\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eReplacement parts under warranty\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e90 d\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top: 14px;\"\u003eA one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.\u003c\/p\u003e\n\n\u003cp\u003eWarranty claims are made through your Enerzone dealer and remain subject to SBI\/Enerzone inspection, approval, and the current written warranty. Kaminos is the retailer for this stove and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer. SBI's parts network is well-stocked — replacement bricks, baffle, secondary tubes, glass, gaskets, and optional blower are openly available at fair prices through multiple parts vendors.\u003c\/p\u003e\n\n\u003cp class=\"warranty-note\"\u003eEnerzone may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.\u003c\/p\u003e\n\n\u003cp class=\"warranty-note\"\u003eCoverage details can change by component and warranty revision; the current Enerzone warranty controls.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCompare with\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eOsburn 2000\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSame SBI medium-large stove performance platform — same firebox class, same combustion chamber, same 20\" log capacity, same 75,000 BTU\/hr maximum, same warranty schedule. The Osburn 2000 is the Osburn-tier counterpart with the Osburn brand finish, a required door overlay choice in Black or Brushed Nickel, and Osburn dealer\/parts positioning. Choose the Solution 2.3 for the Enerzone price point and seven base configurations without the required overlay step; choose the Osburn 2000 if you want the Osburn brand and the overlay finish.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eEnerzone Solution 1.7\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSmaller sibling in the Solution line. 1.86 ft³ firebox, 65,000 BTU\/hr max, 500–1,800 sq ft heating range, 18\" log capacity, 7-hour burn. Choose the Solution 1.7 for heating under 1,500 sq ft; choose the Solution 2.3 for the bigger firebox, 20-inch logs, longer burn time, and primary heat in larger spaces.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003ePacific Energy Super 27\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003ePremium cross-brand competitor in the medium-large stove class. 2.0 ft³ firebox, sealed-firebox technology, premium build, higher price. The most-mentioned cross-shop on hearth-enthusiast forums for buyers comparing mid-to-large non-cat stoves. Higher price; longer real-world burn potential.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cp class=\"pull\"\u003eThe Solution 2.3 is the larger step-up in the Enerzone Solution line. Built for homes that need real heat across real square footage, with 20-inch logs, an 8-hour burn cycle, and a choice of seven base configurations to fit the room. Configure it once, install it right, burn good wood, and it carries you through winter.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Enerzone","offers":[{"title":"Pedestal","offer_id":50191451291841,"sku":"EB00063+AC01124","price":3089.0,"currency_code":"USD","in_stock":true},{"title":"Black Traditional","offer_id":50191451324609,"sku":"EB00063+AC01206","price":2979.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel Traditional","offer_id":50191451357377,"sku":"EB00063+AC01208","price":3419.0,"currency_code":"USD","in_stock":true},{"title":"Black Flared","offer_id":50191451390145,"sku":"EB00063+AC01293","price":3254.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel Flared","offer_id":50191451422913,"sku":"EB00063+AC01294","price":3529.0,"currency_code":"USD","in_stock":true},{"title":"Black Round","offer_id":50191451455681,"sku":"EB00063+AC01295","price":3144.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel Round","offer_id":50191575744705,"sku":"EB00063+AC01296","price":3474.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/3854\/4065\/files\/Enerzone_Solution_2.3_Wood_Stove_Life_Style_Kaminos_1.webp?v=1778527480","url":"https:\/\/kaminos.com\/products\/enerzone-solution-2-3-wood-stove","provider":"Kaminos","version":"1.0","type":"link"}