{"product_id":"osburn-1700-wood-stove","title":"Osburn 1700 Wood Stove","description":"\u003cdiv style=\"font-family: 'Inter', -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color: #231F20; line-height: 1.55; width: 100%; max-width: 100%; box-sizing: border-box; margin: 0; padding: 0; font-size: 16px; overflow-wrap: break-word; word-wrap: break-word; word-break: normal;\"\u003e\n\n\u003cstyle\u003e\n  .km-desc, .km-desc * { box-sizing: border-box; max-width: 100%; }\n  .km-desc { width: 100%; }\n  .km-desc p { margin: 0 0 14px; }\n  .km-desc h3 { font-size: 11px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: 600; color: #9B774D; margin: 22px 0 10px; }\n\n  .km-desc .spec-list { margin: 12px 0 0; }\n  .km-desc .spec-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .spec-row:first-child { border-top: 2px solid #231F20; padding-top: 14px; }\n  .km-desc .spec-label { font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; margin-bottom: 6px; }\n  .km-desc .spec-value { font-weight: 600; font-size: 15px; color: #231F20; margin-bottom: 6px; line-height: 1.35; }\n  .km-desc .spec-meaning { color: #4B484B; font-size: 13px; line-height: 1.55; }\n\n  @media (min-width: 720px) {\n    .km-desc .spec-row { display: grid; grid-template-columns: 38% 30% 1fr; gap: 16px; align-items: start; padding: 12px 0; }\n    .km-desc .spec-label { margin-bottom: 0; align-self: center; }\n    .km-desc .spec-value { margin-bottom: 0; font-size: 14px; align-self: center; }\n    .km-desc .spec-meaning { font-size: 13px; }\n    .km-desc .spec-row:first-child { padding-top: 12px; }\n  }\n\n  .km-desc .data-row { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding: 12px 0; border-bottom: 1px solid rgba(75,72,75,0.12); align-items: baseline; font-size: 13px; }\n  .km-desc .data-head + .data-row { border-top: 2px solid #231F20; }\n  .km-desc .data-row .data-label { color: #4B484B; line-height: 1.4; }\n  .km-desc .data-row .data-val { font-weight: 600; color: #231F20; text-align: right; min-width: 56px; }\n  .km-desc .data-head { display: grid; grid-template-columns: 1fr auto auto; gap: 10px; padding-bottom: 8px; font-size: 10px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: 600; color: #4B484B; }\n  .km-desc .data-head span:nth-child(2), .km-desc .data-head span:nth-child(3) { text-align: right; min-width: 56px; }\n\n  .km-desc ul { list-style: none; padding: 0; margin: 10px 0 14px; }\n  .km-desc ul li { padding: 4px 0 4px 18px; position: relative; line-height: 1.55; }\n  .km-desc ul li:before { content: \"—\"; position: absolute; left: 0; color: #9B774D; font-weight: 500; }\n  .km-desc .callout { background: #D1B382; color: #231F20; padding: 16px 18px; margin: 20px 0; font-size: 13px; line-height: 1.55; }\n  .km-desc .callout-label { font-size: 10px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: 600; margin-bottom: 8px; display: block; }\n  .km-desc .compare-row { padding: 14px 0; border-bottom: 1px solid rgba(75,72,75,0.12); }\n  .km-desc .compare-row:last-child { border-bottom: 0; }\n  .km-desc .compare-name { font-weight: 600; color: #231F20; display: inline-block; padding-bottom: 1px; }\n  .km-desc .compare-orient { color: #4B484B; margin-top: 4px; font-size: 13px; line-height: 1.5; }\n  .km-desc .pull { font-style: italic; font-size: clamp(16px, 4.2vw, 22px); line-height: 1.4; color: #231F20; border-left: 2px solid #9B774D; padding: 0 0 0 16px; margin: 32px 0 16px; }\n  .km-desc .lede { font-size: clamp(16px, 4vw, 22px); line-height: 1.4; letter-spacing: -0.2px; font-weight: 400; color: #231F20; margin: 0 0 24px; }\n  .km-desc .warranty-note { font-size: 12px; color: #4B484B; font-style: italic; margin-top: 14px; }\n  .km-desc details { border-top: 1px solid rgba(75,72,75,0.18); margin: 0; padding: 0; }\n  .km-desc details:last-of-type { border-bottom: 1px solid rgba(75,72,75,0.18); }\n  .km-desc details \u003e summary { list-style: none; cursor: pointer; padding: 18px 32px 18px 0; position: relative; font-size: clamp(16px, 4.2vw, 20px); line-height: 1.3; font-weight: 500; color: #231F20; letter-spacing: -0.2px; }\n  .km-desc details \u003e summary::-webkit-details-marker { display: none; }\n  .km-desc details \u003e summary::after { content: \"+\"; position: absolute; right: 4px; top: 50%; transform: translateY(-50%); font-size: 22px; font-weight: 300; color: #9B774D; line-height: 1; }\n  .km-desc details[open] \u003e summary::after { content: \"−\"; }\n  .km-desc details \u003e summary:focus-visible { outline: 2px solid #9B774D; outline-offset: 4px; }\n  .km-desc details \u003e .acc-body { padding: 0 0 28px 0; }\n\u003c\/style\u003e\n\n\u003cdiv class=\"km-desc\"\u003e\n\n\u003cp class=\"lede\"\u003eA 1.86 ft³ non-catalytic medium-sized freestanding wood stove — the Osburn-branded version of the SBI medium-stove platform shared with the Enerzone Solution 1.7. EPA 2020 cordwood certified at 68% HHV efficiency, with an 18-inch maximum east-west log capacity, mobile-home and alcove approval, 65,000 BTU\/hr maximum output, five base configurations (black traditional legs, black straight legs, black pedestal, brushed-nickel traditional legs, or brushed-nickel straight legs), required door overlay in Black or Brushed Nickel, optional glass ash lip, built-in ash drawer, top heat deflector, and an optional 130 CFM variable-speed blower.\u003c\/p\u003e\n\n\u003cdetails open\u003e\n\u003csummary\u003eWho this is for\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003ch3\u003eRight buyer\u003c\/h3\u003e\n\u003cp\u003eOwners of medium-sized homes, cabins, well-insulated open-plan single-story spaces, or finished basement\/main-floor combinations of roughly 800–1,600 sq ft, with reasonable insulation and access to seasoned hardwood at 15–20% moisture content. Mobile-home and manufactured-home owners — this stove is certified for mobile-home installation with the required fresh-air intake kit and insulated intake pipe.\u003c\/p\u003e\n\u003cp\u003eBuyers who want the Osburn brand finish, dealer\/parts network, and the configurable styling that the Osburn 1700 offers. Five base configurations across two finish colors (Black or Brushed Nickel), two door overlay finishes, and optional glass ash lip — the 1700 has more styling configuration than nearly any other stove in this firebox size class.\u003c\/p\u003e\n\u003cp\u003eBuyers stepping up from the small-stove platform (Osburn 950 or Enerzone Solution 1.4) who need more heat output, longer log capacity, and longer burn cycles. The Osburn 1700 covers heating areas from 500 sq ft on the low end up to 1,800 sq ft on the manufacturer's high end, with a usable tested output band of 9,800–52,200 BTU\/hr.\u003c\/p\u003e\n\u003cp\u003eBuyers who want east-west loading and the wider 17 1\/4-inch door opening that comes with it. The Osburn 1700 is built around a wider-than-it-is-deep firebox; logs go in across the width, sides visible from the door. This is the conventional wood-stove loading orientation — most owners coming from older stoves already know how to load this way.\u003c\/p\u003e\n\n\u003ch3\u003eWrong buyer\u003c\/h3\u003e\n\u003cp\u003eNot for whole-house primary heat in older, drafty, or large homes. The manufacturer's stated 1,800 sq ft upper range is achievable only in well-insulated, open-plan, moderate-climate conditions; in real-world use, comfortable primary heat tops out around 1,400–1,500 sq ft for most homes.\u003c\/p\u003e\n\u003cp\u003eNot for buyers expecting 8+ hour overnight burns. The 7-hour manufacturer maximum burn time is achievable on a packed load of dense hardwood with the air shut down hard, but useful heat from a packed load is realistically 5–6 hours. For longer burns, step up to a larger non-cat firebox (2.5+ ft³) or to a catalytic stove with a true low-output mode.\u003c\/p\u003e\n\u003cp\u003eNot for buyers wanting the smaller stove footprint and reduced clearances of the Osburn 950 or Solution 1.4. The Osburn 1700 is meaningfully larger; if you're heating under 1,000 sq ft and need the smaller stove footprint or N-S loading, look at the 950 instead.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eAt a glance\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cdiv class=\"spec-list\"\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion technology\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eNon-catalytic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eSecondary-air tubes reignite smoke gases. No catalyst to replace; one air-control lever; simpler operation than a cat stove but shorter low-and-slow burn times.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFirebox volume\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e1.86 ft³ overall \/ 1.44 ft³ EPA\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Medium-sized firebox sized for zone heating across 500–1,800 sq ft. The overall figure includes a buffer zone above the EPA loading line; the 1.44 ft³ figure is the usable loading volume used during EPA emissions certification.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum heat output\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e65,000 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePeak output on dry cordwood, transient. Sustained output across a burn cycle is substantially lower.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eTested output range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e9,800–52,200 BTU\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer CSA B415.1-10 stack-loss method. Wide operating band — the low end is genuinely low for a stove this size, useful for shoulder-season heating.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eHeating range\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e500–1,800 sq ft\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer's stated range. Real-world comfort sizing for primary heat is roughly 800–1,500 sq ft in moderate climates and lower in cold climates or older homes — depends on insulation, layout, climate, ceiling height, fuel quality, and installation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAverage efficiency\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e68% HHV \/ 73% LHV\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e76% optimum overall efficiency at low burn rate; 75% optimum heat transfer efficiency. HHV is the federal standard. Government incentives may apply by jurisdiction and installation date.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eParticulate emissions\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e2.4 g\/hr\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eEPA 2020 limits are 2.0 g\/hr crib-wood or 2.5 g\/hr cordwood. The stove is listed as compliant with the 2020 cordwood standard.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum burn time\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eUp to 7 hours\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufacturer maximum at the lowest air setting. Useful heat through a burn cycle is realistically 5–6 hours.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eRecommended log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e16 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003ePer manual. Most firewood suppliers cut to this length.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMaximum log length\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e18 in east-west\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003e2-inch margin over the recommended length. Logs load across the width of the firebox, sides visible from the door.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eConstruction\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eCarbon steel, cast-iron door\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eWelded carbon-steel firebox with an arched cast-iron door frame, decorative side panels, and the Osburn brand finish. Lifetime warranty on the combustion-chamber welds.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eRequired configuration\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eBase + door overlay\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eBase configured at order: black traditional legs, black straight legs, black pedestal, brushed-nickel traditional legs, or brushed-nickel straight legs. Door overlay required in Black (OA10249) or Brushed Nickel (OA10250). Optional glass ash lip available separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eNotable features\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eHeat shield + deflector\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eStainless-steel heat shield added to the C-Cast baffle and a top heat deflector that redirects heat toward the front of the stove. High-density refractory bricks. Built-in ash drawer. Decorative side panels that reduce clearances.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBaffle\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eC-Cast\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eRigid aluminosilicate fiber baffle rated above 2,000 °F. Manual parts list item #51 confirms the C-Cast baffle assembly.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eGlass\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e16 3\/4\" × 10 7\/16\", ceramic\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eArched ceramic glass with air-wash, 5\/32\" (4 mm) thick, tested to 1,400 °F. Replacement glass must be a SCHOTT ceramic with the same specification — no substitute materials.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eBlower\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eOptional, 130 CFM variable speed\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eSold separately. SBI AC01000 130 CFM blower with variable speed control and thermodisc heat sensor for automatic on\/off based on stove temperature. Without the blower, heat distribution relies on radiant heat and natural convection; there is no forced-air circulation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eFlue connection\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e6 in\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eTop of the unit. Performs best on a 6-inch flue. New factory-built chimney systems must meet UL 103 HT (USA) or ULC S629 (Canada); a code-compliant masonry chimney may also be acceptable when properly lined or sized and verified by the installer\/AHJ. Minimum chimney height must follow the current manual, certification label, installer verification, and local code — Osburn documentation may list different minimums by source and configuration. Sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCombustion chamber\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e19 5\/8\" W × 13 1\/2\" D × 11 7\/8\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eInside firebox dimensions per manual. Wider than deep, which is what enables 18\" east-west loading.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eDoor opening\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e17 1\/4\" W × 8 3\/4\" H\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eLoading door opening. The wide door accommodates 18-inch logs loaded east-west.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eMobile home approved\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eYes\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eMobile-home and manufactured-home installations are supported with the required fresh-air intake kit and an insulated intake pipe (HVAC type, ULC S110 or UL 181 class 0\/1). Both are sold separately.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eAlcove install approved\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eYes\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eAlcove installation is approved with double-wall pipe connector. See the manual for specific clearances.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"spec-row\"\u003e\n\u003cdiv class=\"spec-label\"\u003eCountry of origin\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eMade in Canada\u003c\/div\u003e\n\u003cdiv class=\"spec-meaning\"\u003eManufactured by Stove Builder International (SBI) in Saint-Augustin-de-Desmaures, Quebec.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhere it can go\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe Osburn 1700 is approved for installation in residential homes, cabins, sunrooms, alcoves (with double-wall pipe connector), and mobile or manufactured homes (with the required fresh-air intake kit and insulated intake pipe). It is not approved for installation in factory-built (prefab) metal fireplaces or in any outdoor or unconditioned space.\u003c\/p\u003e\n\n\u003ch3\u003eClearances to combustibles\u003c\/h3\u003e\n\u003cp\u003eThe manual specifies clearances based on whether single-wall or double-wall pipe connector is used, and adjusts further for heat-shielded installations and lowered ceilings. With a single-wall pipe connector in a USA installation, the basic clearances are 13\" rear (A), 10\" side (B), and 12\" corner (C). With a double-wall pipe connector, those drop to 6\" \/ 10\" \/ 6\" respectively. With heat shield AC02762 and a double-wall connector, clearances reduce further to 2 1\/2\" on rear, side, and corner measurements, except where the clearance reduction is on the same side as the door handle; in that case, the manual requires at least 6\" from the side wall. Reduced clearances may also be achieved using approved wall heat-shield construction described in the manual; the construction rules and reduction percentages are specific and should be reviewed with your installer before purchase.\u003c\/p\u003e\n\u003cp\u003eAlways confirm the binding clearance figures against the certification label on the back of the stove and your local code. The manual's clearance tables include separate values for Canada and USA, single- and double-wall pipe, with and without heat shields, lowered ceilings, alcoves, and mobile homes.\u003c\/p\u003e\n\n\u003ch3\u003eFloor protection\u003c\/h3\u003e\n\u003cp\u003eFor the Osburn 1700, the manual specifies \u003cstrong\u003eno R-factor required\u003c\/strong\u003e for floor protection — only a continuous, non-combustible material. Approved materials include steel of at least 0.015\" thickness, ceramic tiles sealed together with grout (over a continuous non-combustible sheet beneath), cement board, brick, or any other approved or listed material suited for floor protection. Tile alone is not sufficient — a continuous non-combustible sheet beneath the tile is required.\u003c\/p\u003e\n\u003cp\u003eFloor protection dimensions per the manual: in Canada, 18 inches forward of the door opening and 8 inches each side; in the USA, 16 inches forward of the door opening and 8 inches each side. In Canada, the manual also requires ember protection extending at least 18 inches in front of any door and 8 inches on other sides per CSA B365. No floor protection is required if the stove is installed on a non-combustible floor (concrete slab, for example).\u003c\/p\u003e\n\n\u003ch3\u003eChimney and venting\u003c\/h3\u003e\n\u003cp\u003eThe Osburn 1700 performs best on a 6-inch chimney flue system. New factory-built chimney systems must comply with UL 103 HT (USA) or ULC S629 (Canada) and be suitable for solid fuel. The stove may also be connected to a code-compliant masonry chimney, provided the chimney has either a clay liner or a suitably listed stainless-steel liner and the application is verified by a qualified installer. Minimum chimney height must follow the current manual, certification label, installer verification, and local code — Osburn documentation may list different minimums by source and configuration. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally, subject to local code and installer verification.\u003c\/p\u003e\n\u003cp\u003eFor mobile-home installations, single-wall pipe is strictly forbidden — only double-wall pipe is permitted, and a fresh-air intake kit with insulated intake pipe is required. The fresh-air intake pipe (HVAC type) must meet ULC S110 or UL 181 class 0 or class 1.\u003c\/p\u003e\n\n\u003ch3\u003eOutside air\u003c\/h3\u003e\n\u003cp\u003eAn optional fresh-air intake kit is available for code jurisdictions requiring outside combustion air, for tight new-construction homes with mechanical ventilation, and is required for mobile-home installations. Use the AC01291 5-inch fresh-air intake kit for stoves on legs, or the AC01336 for stoves on pedestal. Mobile-home installations also require insulated 5-inch flex pipe (ULC S110 \/ UL 181 class 0 or class 1 insulated HVAC pipe). A smoke detector and carbon monoxide detector are required in the room where the stove is installed.\u003c\/p\u003e\n\n\u003ch3\u003eCode compliance\u003c\/h3\u003e\n\u003cp\u003eCode compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the stove is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. Confirm local requirements before purchasing — particularly in EPA non-attainment counties and in HOA jurisdictions where new wood-burning installs may be restricted.\u003c\/p\u003e\n\n\u003ch3\u003eCalifornia Proposition 65\u003c\/h3\u003e\n\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat's in the box, what you'll add\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003ch3\u003eShips with the stove\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOsburn 1700 wood stove (OB01700) with welded carbon-steel firebox and arched cast-iron glazed door\u003c\/li\u003e\n\u003cli\u003eChoice of base, configured at order: black traditional legs, black straight legs, black pedestal, brushed-nickel traditional legs, or brushed-nickel straight legs\u003c\/li\u003e\n\u003cli\u003eChoice of door overlay, configured at order: Black (OA10249) or Brushed Nickel (OA10250)\u003c\/li\u003e\n\u003cli\u003eBuilt-in ash drawer (sized to the base configuration)\u003c\/li\u003e\n\u003cli\u003eC-Cast baffle and stainless-steel secondary-air tube assembly\u003c\/li\u003e\n\u003cli\u003eStainless-steel heat shield over the C-Cast baffle\u003c\/li\u003e\n\u003cli\u003eTop heat deflector that redirects heat toward the front of the stove\u003c\/li\u003e\n\u003cli\u003eHigh-density refractory firebrick lining\u003c\/li\u003e\n\u003cli\u003eDecorative side panels\u003c\/li\u003e\n\u003cli\u003eOwner's manual and product documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSold separately\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCode-compliant 6-inch chimney system — listed factory-built chimney for new installations, or an approved masonry chimney\/liner configuration where permitted by code and verified by the installer\/AHJ; required venting components are sold separately\u003c\/li\u003e\n\u003cli\u003eSingle-wall or double-wall pipe connector between the stove and chimney — double-wall is required for alcove and mobile-home installations and reduces clearance requirements\u003c\/li\u003e\n\u003cli\u003eHearth pad or floor protection sized to manual specifications, with continuous non-combustible sheet beneath any tile\u003c\/li\u003e\n\u003cli\u003eOptional 130 CFM variable-speed blower with thermodisc heat sensor (SBI AC01000) — adds forced-air circulation to improve heat distribution; without it, heat moves by radiation and natural convection only\u003c\/li\u003e\n\u003cli\u003eOptional glass ash lip — visible glass strip at the door opening; sold separately\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake kit (SBI AC01291 for legs, AC01336 for pedestal) — required for mobile-home installations and for code or mechanical-ventilation requirements\u003c\/li\u003e\n\u003cli\u003e5-inch insulated flex pipe for fresh-air intake (ULC S110 \/ UL 181 class 0 or class 1 insulated HVAC pipe) — required for mobile-home installations\u003c\/li\u003e\n\u003cli\u003eOptional 5-inch fresh-air intake register with airtight damper — useful where local code, airtight-home design, or owner preference calls for a closable outside-air damper; do not close while the stove is in use\u003c\/li\u003e\n\u003cli\u003eOptional rigid fire screen (SBI AC01299) — not permitted for open-door use in the United States or in Canadian provinces\/jurisdictions with particulate-emission limits; never permitted for use in a mobile home; never leave the stove unattended when used with a fire screen\u003c\/li\u003e\n\u003cli\u003eOptional heat shield AC02762 for further clearance reductions to 2 1\/2\" on rear, side, and corner measurements (subject to the door-handle 6\" side-wall exception)\u003c\/li\u003e\n\u003cli\u003ePin-type wood moisture meter — not optional in practice\u003c\/li\u003e\n\u003cli\u003eStove-top or flue thermometer — strongly recommended; not optional in practice\u003c\/li\u003e\n\u003cli\u003eInstallation by an authorized qualified technician (WETT, NFI, or CSIA certified) — required for warranty coverage and often required by code, permit, or insurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eHow it actually performs\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe 65,000 BTU\/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 9,800–52,200 BTU\/hr band per the CSA B415.1-10 stack-loss method. That low-end figure is genuinely useful — 9,800 BTU\/hr is shoulder-season territory, when a smaller stove with a higher minimum output would overheat the room.\u003c\/p\u003e\n\n\u003cp\u003eA realistic burn cycle from a packed load of well-seasoned hardwood produces a fast 30–45 minute warm-up, 2–3 hours of strong sustained heat, then a gradual decline over the next 2–3 hours with a coal bed remaining. Total useful heat from one full pack is realistically 5–6 hours, occasionally approaching the 7-hour manufacturer maximum with dense hardwood, mild weather, and a packed coal bed. Reload onto coals when heat output falls off and the cycle restarts.\u003c\/p\u003e\n\n\u003cp\u003eThe top heat deflector pushes heat toward the front of the stove rather than letting it climb the back wall, which gives noticeably warmer feet in the seating zone — useful in a room where you actually sit close to the stove. The decorative side panels and the rear heat shield allow the reduced clearances the manual specifies, letting the stove sit closer to walls without compromising safety.\u003c\/p\u003e\n\n\u003cp\u003eThe east-west loading is the conventional loading direction for stoves in this size class. The 17 1\/4\" door opening accommodates 18-inch logs comfortably; the 13 1\/2\" interior firebox depth handles a layered E-W load with room to breathe. The Osburn 1700 ships with steel andirons at the front of the firebox — per the manual's EPA loading procedure, the front log should sit just behind the andirons to control the burn rate.\u003c\/p\u003e\n\n\u003cp\u003eThe 130 CFM optional blower is a meaningful step up from the smaller stoves in the catalog. With the blower installed, the variable-speed control lets you dial CFM up or down, and the thermodisc senses stove temperature and runs the blower automatically when the stove is hot. Without the blower, heat distribution relies on radiant heat and natural convection plus the top deflector; for a one-room install, that's often enough. For distribution into adjacent rooms or open-plan spaces, the blower meaningfully helps.\u003c\/p\u003e\n\n\u003cp\u003eAir-wash glass stays largely clear during proper hot burns at moderate-to-high air settings. At low burn rates with marginally seasoned wood, the glass will tar. This is universal to non-catalytic stoves, not specific to Osburn.\u003c\/p\u003e\n\n\u003cp\u003eOfficial Osburn warranty-registration data currently shows 96% satisfaction among the last 35 registered owners.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eTrade-offs to know\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eSame platform as the Enerzone Solution 1.7.\u003c\/strong\u003e The Osburn 1700 and the Enerzone Solution 1.7 share the same SBI medium-stove performance platform — same firebox volume, same combustion-chamber dimensions, same heat output class, same log capacity. The difference between them is brand finish, configurable styling options (door overlays, leg\/pedestal styles, Black\/Brushed Nickel finishes, optional glass ash lip), and dealer\/parts network positioning. The Osburn 1700 also lists a 130 CFM variable-speed blower as the optional accessory; the Solution 1.7's blower option is in a different CFM class. Choose by the brand, finish, and configurability you prefer.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMedium-size firebox, medium burn time.\u003c\/strong\u003e A 1.86 ft³ non-cat stove gives you meaningful heat output across 800–1,500 sq ft, but the 7-hour manufacturer maximum is a maximum — useful heat realistically tops out at 5–6 hours. If you want true 8–10 hour overnight burns, step up to a 2.5+ ft³ non-cat or to a catalytic stove with a real low-output mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe 1,800 sq ft figure is aspirational.\u003c\/strong\u003e The most consistent owner regret across medium stoves is buying for the high end of the manufacturer's heating range. If you need to reliably heat more than ~1,500 sq ft as primary winter heat in a cold climate or older home, step up a firebox size.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBase and door overlay are one-time decisions.\u003c\/strong\u003e Both the base configuration and the door overlay finish are configured at order, not field-swappable. The combinations let the stove fit many room layouts and aesthetics, but choose the configuration that matches the room you're putting it in — measure the desired height and confirm the look before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2.4 g\/hr emissions is mid-pack for the category.\u003c\/strong\u003e The Osburn 1700 is well within the EPA 2020 cordwood limit (2.5 g\/hr) but is not class-leading on emissions. Buyers who specifically want a low-emissions stove for an EPA non-attainment county should compare against premium-tier cross-shops that test below 1.5 g\/hr.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWood quality is not negotiable.\u003c\/strong\u003e The most common \"the stove doesn't heat\" complaint comes from owners running marginally seasoned wood. Secondary combustion works best with dry, properly seasoned fuel, ideally around 15–20% moisture. A pin-type moisture meter is the single best accessory for this stove.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGlass blackens at low burn rates.\u003c\/strong\u003e Universal to non-cat stoves in this firebox class. Daily hot cleanup burns and tolerance for a periodic wipe are part of operating this stove. Owners chasing always-clear glass on long, slow burns should look at catalytic technology.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRefined but configurable, not ornate.\u003c\/strong\u003e The Osburn 1700 has clean modern lines, an arched cast-iron door, decorative side panels, and the Osburn-tier finish detail. With brushed-nickel overlays it reads more contemporary; with traditional cast-iron legs it reads more classic. It is configurable but not ornate. Buyers wanting heavy decorative cast-iron styling should look at premium-tier alternatives.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eOperating reality\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003e\u003cstrong\u003eFirst burns.\u003c\/strong\u003e The first few fires cure the high-temperature paint and condition the internal components. Burn two or three small fires first, then build bigger, hotter fires until the paint smell is gone. The smell can be strong; ventilate the room well and avoid prolonged exposure during cure-in.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eLighting.\u003c\/strong\u003e Open the air control fully and build a small, hot kindling fire. The manual's EPA loading sequence uses split start-up fuel in three rows criss-crossed at 45 degrees, kindling on top in three rows from largest to smallest, then newspaper sheets on top. Let the door stand at 90 degrees for about a minute, then close. In normal use, the goal is the same: establish draft quickly, get the firebox hot, then close the door once the fire is stable.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAir control.\u003c\/strong\u003e Single-lever, located underneath the ash shelf. Push the handle completely to the left for HIGH (open); push completely to the right for LOW (closed). Full open at light-off; gradually closed only after the load is fully engaged and stable secondary flames are established. The manual recommends closing the primary air control by small increments (about 1\/16 inch at a time) over 4–15 minutes after a reload — too fast and the fire smolders.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eReload cadence.\u003c\/strong\u003e 3–4 hours between reloads in active heating use; up to 6 hours for a final overnight pack with the air shut hard. For loading, follow the same principle the manual describes for EPA testing: three logs on the coal bed in east-west orientation with the front log behind the andirons, two more logs on top angled slightly. Open the air for a minute or two before opening the door, open the door slowly to avoid smoke rollout, load onto the coal bed, close the door, and run the air open until the load is fully engaged before reducing the air gradually. Do not elevate the fire by using a grate. Do not put logs in the marked X area between the glass and primary air channel.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAsh management.\u003c\/strong\u003e The Osburn 1700 has a built-in ash drawer system — the ash plug in the firebox floor opens to drop ash into the drawer below. Per the manual, empty every 2–3 days during full-time heating. Always dispose of ash in a tightly covered metal container on a non-combustible surface, well away from combustible materials — ash retains hot embers for days.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGlass cleaning.\u003c\/strong\u003e Damp newspaper dipped in cold ash, or a dedicated ceramic-glass cleaner. Daily wipe during low-burn weather; weekly during high-burn. Black streaks at the lower edge mean wet wood; black uniformly across the glass means burns are running too cool. Do not clean the glass when the stove is hot, and do not strike or slam the glass door shut.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoor and glass gaskets.\u003c\/strong\u003e Per the manual, the door gasket needs replacement when the paper-strip test fails: close the door on a strip of paper and try to pull it out; firm resistance means the gasket is sealing, easy pull means it's time to replace. Test all the way around the door, not just at the latch. The latch mechanism is also adjustable — turn the handle one counterclockwise turn (after removing the split pin with pliers) to increase pressure. Replacement materials run $20–$40; replacement is a 30-minute job. Plan on every 3–5 seasons in regular use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAnnual chimney sweep.\u003c\/strong\u003e Per the manual, the chimney should be cleaned and inspected at least once each year. Inspect every two months during the heating season until you know your creosote-formation rate; monthly is safer for new burners. If buildup reaches 1\/8 inch, sweep immediately. The baffle and secondary tubes lift out for sweep access.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWood seasoning.\u003c\/strong\u003e Hardwood needs 12–24 months split, stacked off the ground, top-covered, with sun and wind on the sides. Don't trust supplier \"seasoned\" claims — use a pin-type moisture meter, split a piece in half, measure the fresh face. Manual target: 15–20% moisture. Wood above 25% will smolder, soot the glass, line the chimney with creosote, and undercut every published efficiency and emissions number on this page.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eBlower maintenance (if installed).\u003c\/strong\u003e Keep the blower intake and fins free of dust and follow the blower kit instructions for service. Do not oil the blower unless the blower manual specifically calls for lubrication. Replacement blowers and related service parts are available through Osburn\/SBI dealers and parts channels if needed years out.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat never to burn.\u003c\/strong\u003e Per the manual and EPA fuel rules: no coal, garbage, yard waste, materials containing rubber or plastic, waste petroleum products, paint or paint thinners, asphalt products, painted or pressure-treated wood, railroad ties, manure or animal remains, plywood, particle board, paper products, asbestos materials, construction or demolition debris, salt-water driftwood, or unseasoned wood. This does not prohibit normal fire starters made from paper, cardboard, sawdust, wax, or similar substances when used only to start a fire. Burning prohibited materials destroys the firebox, voids the warranty, and releases toxic compounds into your home and the chimney.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWarranty and service\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cp\u003eThe Osburn limited lifetime warranty applies to the original retail purchaser only and is non-transferable. The warranty applies to normal residential use only. Proof of purchase (dated bill of sale), model name, and serial number are required for any warranty claim. Online registration is recommended at osburn-mfg.com but not required if a dated invoice is retained.\u003c\/p\u003e\n\n\u003ch3\u003eCoverage by component\u003c\/h3\u003e\n\n\u003cdiv class=\"data-head\"\u003e\n\u003cspan\u003eComponent\u003c\/span\u003e\u003cspan\u003eParts\u003c\/span\u003e\u003cspan\u003eLabor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCombustion chamber welds, cast-iron door frame\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCeramic glass, plating manufacturing defects\u003c\/span\u003e\u003cspan class=\"data-val\"\u003eLifetime\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eSurrounds, heat shields, ash shelf, steel legs, trims, C-Cast baffle, secondary air tubes\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e7 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eHandle assembly, glass retainers, air control mechanism\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e3 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eCarbon-steel firebox components\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e5 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eOptional blower, heat sensors, switches, wiring, electronics\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e2 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003ePaint (peeling), gaskets, insulation, ceramic fiber blankets, and other options\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e1 yr\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"data-row\"\u003e\n\u003cspan class=\"data-label\"\u003eReplacement parts under warranty\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e90 d\u003c\/span\u003e\u003cspan class=\"data-val\"\u003e—\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top: 14px;\"\u003eA one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.\u003c\/p\u003e\n\n\u003cp\u003eWarranty claims are made through your Osburn dealer and remain subject to SBI\/Osburn inspection, approval, and the current written warranty. Kaminos is the retailer for this stove and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer. SBI's parts network is well-stocked — replacement bricks, baffle, secondary tubes, glass, gaskets, and optional blower are openly available at fair prices through multiple parts vendors.\u003c\/p\u003e\n\n\u003cp class=\"warranty-note\"\u003eOsburn may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.\u003c\/p\u003e\n\n\u003cp class=\"warranty-note\"\u003eCoverage details can change by component and warranty revision; the current Osburn warranty controls.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCompare with\u003c\/summary\u003e\n\u003cdiv class=\"acc-body\"\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eEnerzone Solution 1.7\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSame SBI medium-stove performance platform — same firebox class, same combustion chamber, same 18\" E-W log capacity, same warranty schedule, same EPA 2020 certification class. The Solution 1.7 is the plainer Enerzone-tier version with engraved-groove side panels and an arched cast-iron door, six leg\/pedestal options at the Enerzone price point. The Osburn 1700 adds the Osburn brand finish, required door overlay in Black or Brushed Nickel, optional glass ash lip, and the 130 CFM variable-speed blower option. Choose by the brand, configuration, and finish you prefer.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003eOsburn 950\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003eSmaller Osburn-tier model. 1.8 ft³ firebox, 45,000 BTU\/hr max, 250–1,200 sq ft heating range, 17\" N-S log capacity. Choose the Osburn 950 for smaller spaces under 1,000 sq ft and the practical N-S loading; choose the Osburn 1700 for more heating output, 18\" E-W logs, longer burn time, and the configurable base and door-overlay options.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"compare-row\"\u003e\n\u003cspan class=\"compare-name\"\u003ePacific Energy Super 27\u003c\/span\u003e\n\u003cdiv class=\"compare-orient\"\u003ePremium cross-brand competitor in the medium-stove class. Up to 2,200 sq ft heating range, 2.0 ft³ firebox, sealed-firebox technology, premium build, higher price. The most-mentioned cross-shop on hearth-enthusiast forums for buyers comparing mid-size non-cat stoves. Higher price; longer real-world burn potential.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cp class=\"pull\"\u003eThe Osburn 1700 is the medium-sized workhorse in the Osburn line. Heats up to 1,800 sq ft, loads east-west with 18-inch logs, and lets you pick the base and door finish so it fits the room instead of fighting it. Configure it once, install it right, burn good wood, and it does the job for years.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Osburn","offers":[{"title":"Black \/ Traditional Black","offer_id":49274031833281,"sku":"OB01700+OA10249+OA10247","price":2749.0,"currency_code":"USD","in_stock":true},{"title":"Black \/ Pedestal","offer_id":49274046677185,"sku":"OB01700+OA10249+OA10244","price":2804.0,"currency_code":"USD","in_stock":true},{"title":"Black \/ Black","offer_id":49274046709953,"sku":"OB01700+OA10249+OA10245","price":2969.0,"currency_code":"USD","in_stock":true},{"title":"Black \/ Traditional Brushed Nickel","offer_id":49274046742721,"sku":"OB01700+OA10249+OA10248","price":3189.0,"currency_code":"USD","in_stock":true},{"title":"Black \/ Brushed Nickel","offer_id":49274046775489,"sku":"OB01700+OA10249+OA10246","price":3244.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel \/ Traditional Black","offer_id":49274031866049,"sku":"OB01700+OA10250+OA10247","price":2914.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel \/ Pedestal","offer_id":49274046808257,"sku":"OB01700+OA10250+OA10244","price":2969.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel \/ Black","offer_id":49274046841025,"sku":"OB01700+OA10250+OA10245","price":3134.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel \/ Traditional Brushed Nickel","offer_id":49274046873793,"sku":"OB01700+OA10250+OA10248","price":3354.0,"currency_code":"USD","in_stock":true},{"title":"Brushed Nickel \/ Brushed Nickel","offer_id":49274046906561,"sku":"OB01700+OA10250+OA10246","price":3409.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0798\/3854\/4065\/files\/osburn-1700-wood-stove-front-view_3aa89df1-b68c-4e11-8dc9-cb5b3d492d36.webp?v=1748290775","url":"https:\/\/kaminos.com\/products\/osburn-1700-wood-stove","provider":"Kaminos","version":"1.0","type":"link"}