A 2.4 ft³ non-catalytic medium-large freestanding wood stove — the Osburn-branded version of the SBI medium-large stove platform shared with the Enerzone Solution 2.3. EPA 2020 cordwood certified at 72% HHV efficiency, with a 20-inch maximum east-west log capacity, up to 2,100 sq ft of heating area, an 8-hour maximum burn time, mobile-home and alcove approval, 75,000 BTU/hr maximum output, a 130 CFM variable-speed blower included, required door overlay in Black or Brushed Nickel, and a configurable base (multiple leg kits in Black or Brushed Nickel, or pedestal). Choose the options below; the price updates as you go.
- Type: Wood stove, EPA 2020 certified
- Heats: 500–2,100 sq ft
- Heat output: 75,000 BTU/hr
- Log length: 16 in east-west
- Efficiency: 72% HHV / 77% LHV
- Burn time: Up to 8 hours
- Chimney: 6 in
- Made by: Osburn, by Stove Builder International, Quebec, Canada
Who it's for
Right buyer. Owners of medium-to-larger homes, well-insulated open-plan two-story spaces, or one stove serving as primary winter heat across 1,200–1,800 sq ft of conditioned space, with reasonable insulation and access to seasoned hardwood at 15–20% moisture content. Mobile-home and manufactured-home owners — this stove is certified for mobile-home installation with the required fresh-air intake kit and insulated intake pipe. Buyers who want the Osburn brand finish, the configurable styling, and the 130 CFM blower included as standard. The Osburn 2000 ships with the blower included rather than as a separate accessory — a meaningful platform difference vs the Enerzone Solution 2.3 sibling, where the blower is optional and sold separately.
Buyers stepping up from the Osburn 1700 medium-stove platform who want a meaningful firebox jump, longer 20-inch logs, and longer burn cycles. The Osburn 2000 covers heating areas from 500 sq ft on the low end up to 2,100 sq ft on the manufacturer's high end, with a tested output band of 14,200–44,500 BTU/hr. Buyers who want east-west loading and the wider 17 1/2-inch door opening that comes with it. The Osburn 2000 is built around a wider-than-it-is-deep firebox; logs go in across the width, sides visible from the door. Per the manual, the firebox depth of 16 1/2" also accepts north-south loading for packed high-output cold-weather cycles.
Wrong buyer. Not for buyers heating under 1,000 sq ft. The Osburn 2000 is meaningfully larger than the Osburn 950 or 1700; in a small room it will overheat at almost any meaningful burn rate. If you're heating a small space, look at the Osburn 950 or 1700 instead. Not for buyers expecting 10+ hour overnight burns. The 8-hour manufacturer maximum is achievable on a packed load of dense hardwood with the air shut down hard, but useful heat from a packed load is realistically 6–7 hours. For longer burns, step up to a 3.0+ ft³ firebox or to a catalytic stove with a real low-output mode. Not for buyers wanting heavy decorative cast-iron styling. The Osburn 2000 has clean lines, an arched cast-iron door, and the Osburn brand finish, but it is not an ornate cast-iron showpiece. Buyers who want furniture-grade cast iron should look at premium-tier alternatives.
Will it fit?
Dimensions from the specification sheet
| Measurement | Value |
|---|---|
| Overall height | 33‑1/8" |
| Overall width | 27" |
| Overall depth | 29" |
| Shipping weight | 390 shipping lb |
| Glass, W x H | 17‑1/8 x 10‑1/4 |
| Door opening | 17‑1/2 W x 9 H |
| Firebox, W x H x D | 21 W x 11‑7/8 H x 16‑3/4 D |
Dimensions
| Measurement | Value |
|---|---|
| Firebox volume | 2.4 ft³ overall / 1.95 ft³ EPA |
| Glass | Viewable glass surface, ceramic |
| Door opening | 17 1/2" W x 9" H |
| Shipping weight | 390 lb (without option) |
Where it can go
The Osburn 2000 is approved for installation in residential homes, cabins, sunrooms, alcoves (with double-wall pipe connector), and mobile or manufactured homes (with the required fresh-air intake kit and insulated intake pipe). It is not approved for installation in factory-built (prefab) metal fireplaces or in any outdoor or unconditioned space.
Clearances to combustibles
Floor protection
For the Osburn 2000, the manual specifies no R-factor required for floor protection — only a continuous, non-combustible material. Approved materials include steel of at least 0.015" thickness, ceramic tiles sealed together with grout (over a continuous non-combustible sheet beneath), cement board, brick, or any other approved or listed material suited for floor protection. Tile alone is not sufficient — a continuous non-combustible sheet beneath the tile is required.
Floor protection dimensions per the manual: in Canada, 18 inches forward of the door opening and 8 inches each side; in the USA, 16 inches forward of the door opening and 8 inches each side. In Canada, the manual also requires ember protection extending at least 18 inches in front of any door and 8 inches on other sides per CSA B365. No floor protection is required if the stove is installed on a non-combustible floor (concrete slab, for example).
Clearances
United States figures, in inches. The rating plate on the appliance overrides any published number; the installer confirms on site.
| Clearance | Minimum |
|---|---|
| Back wall, single-wall pipe | 11" |
| Back wall, double-wall pipe | 6" |
| Corner, single-wall pipe | 10" |
| Corner, double-wall pipe | 7" |
| Side wall | 16" |
| Ceiling, from the floor the stove sits on | 84" |
| Floor protection in front | 16" |
Notes from the manual
The manual specifies clearances based on whether single-wall or double-wall pipe connector is used, and adjusts further for heat-shielded installations and lowered ceilings. The manual's clearance tables include separate values for Canada and USA, single- and double-wall pipe, with and without heat shields, lowered ceilings, alcoves, and mobile homes. Where the clearance reduction is on the same side as the door handle, the manual requires a minimum 6-inch clearance from the side wall — review with your installer before purchase. Reduced clearances may also be achieved using approved wall heat-shield construction described in the manual; the construction rules and reduction percentages are specific to the configuration.
Always confirm the binding clearance figures against the certification label on the back of the stove and your local code.
Heat and burn
From the specification sheet
| Spec | Value |
|---|---|
| Heating area | 500 to 2,100 sq ft |
| Maximum heat output | 75,000 BTU/h |
| Heat output range | 14,800 to 28,600 BTU/h |
| Efficiency | 69% HHV, 74% LHV average; 77% optimum |
| Burn time | 8 h |
| Firebox volume | 2.4 cu ft (EPA loading 2.02) |
| Log length | 20 in (16 in recommended) |
| Emissions | 1.54 g/h |
| Blower | 130 CFM included |
| Spec | Value | What it means |
|---|---|---|
| Combustion technology | Non-catalytic | Secondary-air tubes reignite smoke gases. No catalyst to replace; one air-control lever; simpler operation than a cat stove but shorter low-and-slow burn times. |
| Maximum heat output | 75,000 BTU/hr | Peak output on dry cordwood, transient. Sustained output across a burn cycle is substantially lower. |
| Heating range | 500–2,100 sq ft | Manufacturer's stated range. Real-world comfort sizing for primary heat is roughly 1,200–1,800 sq ft in moderate climates and lower in cold climates or older homes — depends on insulation, layout, climate, ceiling height, fuel quality, and installation. |
| Average efficiency | 72% HHV / 77% LHV | 79% optimum overall efficiency at low burn rate; 76% optimum heat transfer efficiency. HHV is the federal standard. Government incentives may apply by jurisdiction and installation date. |
| Particulate emissions | 2.3 g/hr | EPA 2020 limits are 2.0 g/hr crib-wood or 2.5 g/hr cordwood. The stove is listed as compliant with the 2020 cordwood standard. |
| Maximum burn time | Up to 8 hours | Manufacturer maximum at the lowest air setting. Useful heat through a burn cycle is realistically 6–7 hours. |
| Recommended log length | 16 in east-west | Per manual. Most firewood suppliers cut to this length. |
| Maximum log length | 20 in east-west | 4-inch margin over the recommended length — meaningful for buyers with access to longer-cut firewood. Logs load across the width of the firebox, sides visible from the door. |
| Combustion chamber | 21" W x 16 1/2" D x 11 7/8" H | Inside firebox dimensions per manual. Wider than deep; the 16 1/2" depth is generous enough to accept N-S loading for packed cold-weather cycles in addition to the default E-W loading. |
Choose your options
Options
The unit price is Osburn's 2026 list price for the wood stove alone. Options sold on this page add to it; those marked on request we add to your order by hand.
Door overlay
| Door overlay | Part | Price |
|---|---|---|
| BLACK DOOR OVERLAY | OA10237 | $110 |
| BRUSHED NICKEL DOOR OVERLAY | OA10238 | $330 |
Base
| Base | Part | Price |
|---|---|---|
| BLACK CAST IRON TRADITIONAL LEGS WITH ASH DRAWER | OA10226 | $330 |
| BRUSHED NICKEL CAST IRON TRADITIONAL LEGS WITH ASH DRAWER | OA10228 | $765 |
| BLACK CAST IRON STRAIGHT LEGS WITH ASH DRAWER | OA10235 | $550 |
| BRUSHED NICKEL CAST IRON STRAIGHT LEGS WITH ASH DRAWER | OA10236 | $825 |
| PEDESTAL WITH ASH DRAWER | OA10239 | $440 |
| 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE ON LEGS (on request) | AC01211 | $220 |
| 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE ON PEDESTAL (on request) | AC01336 | $120 |
Fresh air
| Fresh air | Part | Price |
|---|---|---|
| 5''Ø FRESH AIR INTAKE REGISTER WITH AIRTIGHT DAMPER (on request) | AC01349 | $285 |
| 5"Ø X 4' INSULATED FLEX PIPE FOR FRESH AIR INTAKE (on request) | AC02090 | $50 |
Other options
| Other options | Part | Price |
|---|---|---|
| RIGID FIRESCREEN (on request) | AC01315 | $200 |
| QUICK CONNECT THERMODISC (on request) | AC02055 | $80 |
| TEMPERED GLASS HEARTH PAD 10 mm - 54" X 46 3/4" (on request) | AC02703 | $869 |
| MODULAR FLOOR PROTECTION SYSTEM 54" X 46 3/4" (on request) | AC02711 | $545 |
| TINTED TEMPERED GLASS HEARTH PAD 10 mm - 54" X 46 3/4" (on request) | AC02758 | $439 |
| BLACK STEEL HEARTH PAD 46 3/4'' X 54" (on request) | AC02788 | $420 |
| GLASS ASH LIP (on request) | OA10132 | $165 |
Chimney and installation
Chimney requirements from the specification sheet
| Requirement | Value |
|---|---|
| Flue | 6 in |
| Chimney type | CAN/ULC S629, UL 103 HT |
| Minimum chimney height | 12 ft |
| Alcove installation | yes |
| Mobile home installation | yes, with fresh air intake |
The Osburn 2000 performs best on a 6-inch chimney flue system. New factory-built chimney systems must comply with UL 103 HT (USA) or ULC S629 (Canada) and be suitable for solid fuel. The stove may also be connected to a code-compliant masonry chimney, provided the chimney has either a clay liner or a suitably listed stainless-steel liner and the application is verified by a qualified installer. Minimum chimney height must follow the current manual, certification label, installer verification, and local code. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally, subject to local code and installer verification.
For mobile-home installations, single-wall pipe is strictly forbidden — only double-wall pipe is permitted, and a fresh-air intake kit with insulated intake pipe is required. The fresh-air intake pipe (HVAC type) must meet ULC S110 or UL 181 class 0 or class 1.
Outside air
An optional fresh-air intake kit is available for code jurisdictions requiring outside combustion air, for tight new-construction homes with mechanical ventilation, and is required for mobile-home installations. Mobile-home installations also require insulated 5-inch flex pipe (ULC S110 / UL 181 class 0 or class 1 insulated HVAC pipe). A smoke detector and carbon monoxide detector are required in the room where the stove is installed.
Codes and approvals
Code compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the stove is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. Confirm local requirements before purchasing — particularly in EPA non-attainment counties and in HOA jurisdictions where new wood-burning installs may be restricted.
California Proposition 65
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.
What arrives
- Osburn 2000 wood stove (OB02015) with welded carbon-steel firebox and arched cast-iron glazed door
- Choice of base, configured at order: multiple cast-iron leg styles in Black or Brushed Nickel, or pedestal — each with built-in ash drawer
- Choice of door overlay, configured at order: Black or Brushed Nickel
- 130 CFM variable-speed blower with rheostat control (HI/LO/OFF)
- Decorative side panels
- C-Cast baffle and stainless-steel secondary-air tube assembly
- High-density refractory firebrick lining
- Ash lip pan
- Owner's manual and product documentation
Sold separately
- Code-compliant 6-inch chimney system — listed factory-built chimney for new installations, or an approved masonry chimney/liner configuration where permitted by code and verified by the installer/AHJ; required venting components are sold separately
- Single-wall or double-wall pipe connector between the stove and chimney — double-wall is required for alcove and mobile-home installations and reduces clearance requirements
- Hearth pad or floor protection sized to manual specifications, with continuous non-combustible sheet beneath any tile
- Optional thermodisc heat sensor — automatic on/off control for the included blower based on stove temperature
- Optional ash lip glass panel — visible glass strip at the door opening
- Optional 5-inch fresh-air intake kit — required for mobile-home installations and for code or mechanical-ventilation requirements; separate part numbers for stoves on legs vs pedestal
- 5-inch insulated flex pipe for fresh-air intake (ULC S110 / UL 181 class 0 or class 1 insulated HVAC pipe) — required for mobile-home installations
- Optional 5-inch fresh-air intake register with airtight damper — useful where local code, airtight-home design, or owner preference calls for a closable outside-air damper; do not close while the stove is in use
- Optional rigid fire screen (SBI AC01315) — not permitted for open-door use in the United States or in Canadian provinces/jurisdictions with particulate-emission limits; never permitted for use in a mobile home; never leave the stove unattended when used with a fire screen
- Optional heat shield for further clearance reductions (subject to the door-handle 6" side-wall exception per manual)
- Pin-type wood moisture meter — not optional in practice
- Stove-top or flue thermometer — strongly recommended; not optional in practice
- Installation by an authorized qualified technician (WETT, NFI, or CSIA certified) — required for warranty coverage and often required by code, permit, or insurance
Before you order
- Check with your building department and insurer: wood appliances need a permit in most places and an inspection after installation.
- The chimney is the other half of the system. It is sold separately and quoted from your installer's plan.
- Clearances and floor protection come from the manual and depend on the pipe and shields you choose. Send us your plan and we will check it.
- Burn seasoned wood below 20 percent moisture. Wet wood is the cause of most complaints about any wood stove.
- Special-order goods ship by freight.
How it performs
The 75,000 BTU/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 14,200–44,500 BTU/hr band per the CSA B415.1-10 stack-loss method — a usable range that covers shoulder-season heating on the low end and serious cold-snap output on the high end.
A realistic burn cycle from a packed load of well-seasoned hardwood produces a fast 30–45 minute warm-up, 2–3 hours of strong sustained heat, then a gradual decline over the next 3–4 hours with a coal bed remaining. Total useful heat from one full pack is realistically 6–7 hours, occasionally approaching the 8-hour manufacturer maximum with dense hardwood, mild weather, and a packed coal bed. Reload onto coals when heat output falls off and the cycle restarts.
The 20-inch maximum log capacity is the meaningful differentiator vs the smaller Osburn 1700 (18 in). Most firewood suppliers cut to 16 inches as standard, but 20-inch capacity gives real margin — a buyer with access to longer-cut wood gets four extra inches of fuel per log without juggling. East-west loading is the default; per the manual, north-south loading is also possible thanks to the 16 1/2" firebox depth, and the manual specifically recommends N-S loading for packed cold-weather cycles where you want to fit the maximum amount of wood.
The included 130 CFM variable-speed blower is a meaningful step up from buying the Osburn 1700 or Osburn 950 and adding a blower separately. The rheostat lets you dial speed from HIGH down to LOW or fully OFF. Per the manual, allow the stove to reach operating temperature (approximately one hour from a cold start) before turning on the blower; turning the blower on too early pulls heat away from the firebox during the start-up phase and slows the build-up to clean combustion. With the optional thermodisc installed, the blower starts and stops automatically based on stove temperature — leave the rheostat at the desired speed setting and let the thermodisc handle the rest.
Air-wash glass stays largely clear during proper hot burns at moderate-to-high air settings. At low burn rates with marginally seasoned wood, the glass will tar. This is universal to non-catalytic stoves, not specific to Osburn.
Trade-offs to know
Same platform as the Enerzone Solution 2.3. The Osburn 2000 and the Enerzone Solution 2.3 share the same SBI medium-large stove performance platform — same firebox, same combustion-chamber dimensions, same 20-inch log capacity, same 75,000 BTU/hr maximum output. The Osburn 2000 includes the 130 CFM blower as standard (on the Solution 2.3 it's optional and sold separately), adds the required door overlay configuration in Black or Brushed Nickel, and brings the Osburn brand finish and dealer/parts network. Choose the Osburn 2000 if you want the blower included, the Osburn brand, and the required-overlay finish; choose the Solution 2.3 for the Enerzone price point without the required overlay step.
Medium-large firebox, medium-long burn time. A 2.4 ft³ non-cat stove gives you meaningful primary-heat capability across 1,200–1,800 sq ft, with realistic 6–7 hour burn cycles. If you want true 10+ hour overnight burns or 2,500+ sq ft primary heating, step up to a 3.0+ ft³ firebox or to a catalytic stove with a real low-output mode.
The 2,100 sq ft figure is aspirational. The most consistent owner regret across medium-large stoves is buying for the high end of the manufacturer's heating range. If you need to reliably heat more than ~1,800 sq ft as primary winter heat in a cold climate or older home, step up a firebox size — the Osburn 3500 gives meaningfully more usable heat for the same operational effort.
Base and door overlay are one-time decisions. Both the base configuration and the door overlay finish are configured at order, not field-swappable. The combinations let the stove fit many room layouts and aesthetics, but choose the configuration that matches the room you're putting it in — measure the desired height and confirm the look before ordering.
2.3 g/hr emissions is mid-pack for the category. The Osburn 2000 is well within the EPA 2020 cordwood limit (2.5 g/hr) but is not class-leading on emissions. Buyers who specifically want a low-emissions stove for an EPA non-attainment county should compare against the Osburn Matrix (same platform, lower published emissions) or premium-tier cross-shops that test below 1.5 g/hr.
Wood quality is not negotiable. The most common "the stove doesn't heat" complaint comes from owners running marginally seasoned wood. Secondary combustion works best with dry, properly seasoned fuel, ideally around 15–20% moisture. A pin-type moisture meter is the single best accessory for this stove.
Glass blackens at low burn rates. Universal to non-cat stoves. Daily hot cleanup burns and tolerance for a periodic wipe are part of operating this stove. Owners chasing always-clear glass on long, slow burns should look at catalytic technology.
Refined but configurable, not ornate. The Osburn 2000 has clean modern lines, an arched cast-iron door, decorative side panels, and the Osburn-tier finish. With brushed-nickel overlays it reads more contemporary; with black cast-iron legs it reads more classic. It is configurable but not ornate. Buyers wanting heavy decorative cast-iron styling should look at premium-tier alternatives.
Living with it
First burns. The first few fires cure the high-temperature paint and condition the internal components. Burn two or three small fires first, then build bigger, hotter fires until the paint smell is gone. The smell can be strong; ventilate the room well and avoid prolonged exposure during cure-in.
Lighting. The manual recommends a top-down fire as the most effective method: two small (~1") pieces on each side of the firebox, crumpled newspaper between them, more small pieces crossed over the newspaper, then five medium-sized (2-3") pieces crossed on top in two layers. Open the air control fully and light the newspaper. Leave the door slightly ajar for about five minutes. Close the door when the fire is well lit, keeping the air intake control open. Add larger pieces once the medium pieces are burning well.
Air control. Single-lever, located underneath the ash shelf. Push the handle completely to the left for HIGH (open); push completely to the right for LOW (closed). Full open at light-off; gradually closed only after the load is fully engaged and stable secondary flames are established. The manual specifies closing the primary air control by small increments (about 1/16 inch at a time) between 4 and 15 minutes after a reload — too fast and the fire smolders.
Reload cadence. 3–4 hours between reloads in active heating use; up to 7 hours for a final overnight pack with the air shut hard. For loading, follow the principle the manual describes: rake remaining charcoal toward the door before loading, then load three logs on the coal bed in east-west orientation with 1–2 inches of air space from the rear firebrick, and two more logs on top angled slightly. Open the air for a minute or two before opening the door, open the door slowly to avoid smoke rollout, load, close the door, and run the air open until the load is fully engaged before reducing the air gradually. Do not elevate the fire by using a grate. Always operate the stove with the ash drawer closed.
Burn in cycles, not single-log feeds. The manual is explicit: do not attempt to produce steady heat output by placing a single log on the fire at regular intervals. Always place at least three (preferably more) pieces on the fire at a time so the heat radiated from one piece helps ignite the pieces next to it. Each load should provide several hours of heating.
Ash management. The Osburn 2000 has a built-in ash drawer system (included with each base configuration) — the ash plug in the firebox floor opens to drop ash into the drawer below. Per the manual, empty every 2–3 days during full-time heating. The best time to remove ash is after an overnight fire when the stove is relatively cool but there is still some chimney draft to draw ash dust into the stove rather than into the room. Always dispose of ash in a tightly covered metal container on a non-combustible surface, well away from combustible materials — ash retains hot embers for days. Never store ashes indoors, in a non-metallic container, or on a wooden deck.
Glass cleaning. Damp newspaper dipped in cold ash, or a dedicated ceramic-glass cleaner. Daily wipe during low-burn weather; weekly during high-burn. Black streaks at the lower edge mean wet wood; black uniformly across the glass means burns are running too cool. Brown stains at the lower corners mean smoky combustion. Do not clean the glass when the stove is hot, and do not strike or slam the glass door shut.
Door and glass gaskets. Per the manual, the door gasket needs replacement when the paper-strip test fails: close the door on a strip of paper and try to pull it out; firm resistance means the gasket is sealing, easy pull means it's time to replace. Test all the way around the door, not just at the latch. The latch mechanism is also adjustable — turn the handle one counterclockwise turn (after removing the split pin with pliers) to increase pressure. Replacement materials run $20–$40; replacement is a 30-minute job. Plan on every 3–5 seasons in regular use.
Specifications
| Combustion technology | Non-catalytic |
|---|---|
| Firebox volume | 2.4 ft³ overall / 1.95 ft³ EPA |
| Maximum heat output | 75,000 BTU/hr |
| Tested output range | 14,200–44,500 BTU/hr |
| Heating range | 500–2,100 sq ft |
| Average efficiency | 72% HHV / 77% LHV |
| Particulate emissions | 2.3 g/hr |
| Maximum burn time | Up to 8 hours |
| Recommended log length | 16 in east-west |
| Maximum log length | 20 in east-west |
| Construction | Carbon steel, cast-iron door |
| Required configuration | Base + door overlay |
| Baffle | C-Cast |
| Glass | Viewable glass surface, ceramic |
| Blower | Included, up to 130 CFM variable speed |
| Flue connection | 6 in |
| Combustion chamber | 21" W x 16 1/2" D x 11 7/8" H |
| Door opening | 17 1/2" W x 9" H |
| Shipping weight | 390 lb (without option) |
| Mobile home approved | Yes |
| Alcove install approved | Yes |
| Country of origin | Made in Canada |
| Model | OB02015 |
| Manufacturer | Osburn, by Stove Builder International (SBI), Quebec, Canada |
| Certification | UL 1482, UL 737, ULC S627; EPA 2020; CSA B415.1‑10 |
| Warranty | Limited lifetime |
| Specification source | SBI specification table as published by Osburn dealers (ruralenergy.com, firepitsurplus.com, rockfordchimneysupply.com), 2026 |
Warranty
A one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.
Warranty claims are made through your Osburn dealer and remain subject to SBI/Osburn inspection, approval, and the current written warranty. Kaminos is the retailer for this stove and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer. SBI's parts network is well-stocked — replacement bricks, baffle, secondary tubes, glass, gaskets, and blower components are openly available at fair prices through multiple parts vendors.
Osburn may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.
Coverage details can change by component and warranty revision; the current Osburn warranty controls.
Questions people ask
How does it compare with the other Osburn models?
- Enerzone Solution 2.3 Same SBI medium-large stove performance platform — same firebox class, same combustion chamber, same 20" log capacity, same 75,000 BTU/hr maximum, same warranty schedule, same EPA 2020 certification class. The Solution 2.3 is the plainer Enerzone-tier version with seven base configurations at the Enerzone price point, blower optional and sold separately, no required door overlay step. The Osburn 2000 adds the Osburn brand finish, the required door overlay choice in Black or Brushed Nickel, and the 130 CFM blower included as standard. Choose by the brand, finish, and whether you want the blower included or as a separate purchase.
- Osburn 1700 Smaller Osburn-tier model. 1.86 ft³ firebox, 65,000 BTU/hr max, 500–1,800 sq ft heating range, 18" log capacity, 7-hour burn, blower optional. Choose the Osburn 1700 for heating under 1,500 sq ft and the smaller footprint; choose the Osburn 2000 for the bigger firebox, 20-inch logs, longer burn time, primary heat in larger spaces, and the included blower.
- Osburn Matrix Same SBI medium-large platform as the Osburn 2000 with contemporary European styling, an optional steel or Quebec-soapstone top and side panels, and lower published emissions of 1.54 g/hr. Includes the same 130 CFM blower. Choose the Matrix if you want the modern aesthetic and class-leading emissions; choose the Osburn 2000 if you want the traditional arched cast-iron door look at a lower price point.
- Pacific Energy Super 27 Premium cross-brand competitor in the medium-large stove class. 2.0 ft³ firebox, sealed-firebox technology, premium build, higher price. The most-mentioned cross-shop on hearth-enthusiast forums for buyers comparing mid-to-large non-cat stoves. Higher price; longer real-world burn potential.
What chimney does it take?
A 6-inch flue: a listed factory-built chimney rated UL 103 HT in the US or ULC S629 in Canada, or a lined masonry chimney in good repair. The connector pipe and chimney are quoted from your installer's plan.
Does it need a blower?
No. Every Osburn heats by radiation and natural convection. The optional blower moves warm air into the room faster and helps in a larger or open space; it needs a 120-volt outlet.
Can I install it myself?
Many owners do the placement and the pipe with the manual in hand, but the chimney, the permit and the inspection are where an installer earns the fee. Insurance usually requires the inspection.
Can I return it?
Stoves ship by freight. Confirm the model and the options with us before you order, and contact us before returning anything.
What wood should I burn?
Seasoned hardwood, split and dried a year or more, below 20 percent moisture. Wet wood smokes, coats the chimney with creosote and makes a poor fire.
How often does the chimney need sweeping?
Once a year at least, and after every cord or two if you burn nightly.
Can it go in a mobile home or an alcove?
The specification table on this page says whether the model is approved for a mobile home, with the fresh-air kit, and for an alcove, with the alcove clearances in the manual.
If you have any questions about this product, please let us know by filling out the form below, and we will contact you as soon as possible.
- Choosing a selection results in a full page refresh.