A 4.28 ft³ non-catalytic zero-clearance wood-burning fireplace with an included 176 CFM blower, 25-inch maximum east-west log capacity, and a wide 29 3/4" × 13" double glass door. EPA 2020 cordwood certified at 64% HHV efficiency and 1.6 g/hr emissions, with up to 11-hour maximum burn and 95,000 BTU/hr peak output. Built into a new or properly rebuilt framed chase as primary winter heat for properly vented homes in the 1,500–2,500 sq ft real-world range. One buyer-configurable choice at order: louver style (Traditional or Rustic).
Who this is for
Right buyer
Owners of moderately to well-insulated homes between roughly 1,500 and 2,500 sq ft who want a wood-burning fireplace built into the wall with the high heat output and EPA 2020 cordwood compliance of a serious heating appliance, not a decorative-only fireplace.
New-construction buyers framing a fireplace chase from scratch per the install manual's dimensions, OR substantial-renovation buyers replacing an aging factory-built prefab fireplace where the existing chase framing and chimney can be verified or rebuilt to meet the Solution 4.5 ZC's specific requirements. Replacement is not a drop-in: the old prefab unit must come out completely, the old chimney must be removed or replaced with an approved 8-inch UL 103 HT / ULC S629 system, and the existing chase framing must meet the published framing dimensions and clearances or be rebuilt to meet them. The unit cannot slide into an existing prefab firebox and cannot reuse an unapproved chimney or framing system. It is a zero-clearance fireplace — it ships with listed insulation, shielding, and standoffs that allow installation inside a framed combustible chase when the manual's framing dimensions, clearances, air spaces, chimney system, and finish-material requirements are followed.
Buyers who want a true heating fireplace rather than a built-in decorative box. The 4.28 ft³ firebox, 95,000 BTU/hr peak output, 25-inch log capacity, and included 176 CFM blower put this in serious primary-heat territory for a fireplace — well above typical decorative ZC fireplaces, which are not EPA-certified heating appliances.
Buyers who want the wide modern aesthetic — clean rectangular glass, double cast-iron-framed doors, choice of Traditional or Rustic louver style — and who plan to integrate the fireplace as the architectural focal point of a living room, great room, or open-plan family room.
Wrong buyer
Not for buyers retrofitting an existing masonry fireplace — that is a wood insert's job, not a zero-clearance fireplace. Look at the Osburn Matrix 2700 or Enerzone Destination 2.7 if you have a masonry opening and want to upgrade its heating performance.
Not for buyers who want set-and-forget heating. Wood fireplaces require active operation: lighting, monitoring flue temperature, closing the air at the right moment, deciding when to reload. The fireplace can leave usable coals by morning, but do not expect steady, high output through an entire night.
Not for buyers expecting 14–20+ hour overnight burns. Non-catalytic appliances give you 7–10 hours of useful heat from a packed firebox of dense hardwood; for longer burns, a catalytic stove is the right tool. The manufacturer-claimed 11-hour maximum is strong for a non-cat at this firebox size — useful heat through that cycle is realistically 8–10 hours.
Not for buyers without space for an 8-inch chimney system. Most EPA-certified non-cat appliances at smaller firebox volumes use a 6-inch chimney; this larger firebox requires an 8-inch system, which is bulkier through the wall or roof and costs more in chimney materials.
Not for mobile-home or manufactured-home installation. This fireplace is NOT mobile-home approved.
Not for small spaces under 1,200 sq ft — at this firebox volume the fireplace will easily overheat the room at any meaningful burn rate, forcing low burns that smolder, blacken the glass, and produce creosote.
At a glance
Where it can go
The Solution 4.5 ZC is designed for installation in a permitted residential space — a living room, great room, family room, or any habitable room with adequate floor and wall framing to accept the zero-clearance chase and the 8-inch chimney system. It is not approved for mobile or manufactured-home installation, drop-in replacement of an existing prefab/decorative fireplace (the unit cannot slide into an existing prefab firebox and cannot reuse the old chimney or framing if those do not meet the published requirements), or outdoor or unconditioned-space installation. Replacement installs are possible only when the old fireplace and chimney are fully removed and the chase is verified or rebuilt to meet the required framing dimensions, clearances, and the approved 8-inch UL 103 HT / ULC S629 chimney requirement.
This is a zero-clearance unit — it ships with listed insulation, shielding, and standoffs that allow installation inside a framed combustible chase when the manual's framing dimensions, clearances, air spaces, chimney system, and finish-material requirements are followed. No masonry shell is required, but no surface of the firebox or chimney connection is permitted to touch combustible material outside the manual's listed zones. Garage, shop, cabin, or non-residential installations should be cleared with the AHJ, insurer, and authorized installer before purchase.
Clearances to combustibles
Clearances apply identically in Canada and the USA per the manufacturer's clearance table. The certification label on the unit is the binding clearance for any installation and always overrides clearance figures published in any other media. Some appliances have been tested with a low ceiling — refer to the installation manual for reduced-ceiling configurations. Confirm the binding clearance figures with your installer before purchase.
Framing and finish
A framed chase built per the install manual's framing dimensions is required. The chase width must account for the fireplace body plus space for accessory routing — the install manual specifies adding 6 inches for the fresh-air intake pipe (if used) and 10 inches for forced-air pipe (if used) to the width of the chase, plus the thickness of any drywall panels or finishing material inside the chase around the fireplace. Plan the chase dimensions with the installer before framing begins.
Finish material around the fireplace opening must be non-combustible within the manual's specified zones — typically a combination of cement board, stone or tile veneer, brick, or steel. Combustible material (wood mantles, decorative trim, paneling) is permitted outside those non-combustible zones at the specified distances. The included black faceplate and the louver style selected at order (Traditional default or Rustic upgrade) form the finished edge between the fireplace and the surrounding wall material.
Floor protection / hearth extension
A hearth extension is required if the fireplace is installed directly on the floor or on a raised base of less than 4 inches. The hearth extension must be a continuous non-combustible material extending at least 18 inches in front with an R-value equal to or greater than 1.00 — for example, 1/2-inch Micore or equivalent insulation specified in the manual. The optional Tempered Glass Hearth Pad (SBI AC02760, 18" × 50") is a manufacturer-supplied option pre-sized for this requirement. If the fireplace sits on a raised base of 4 inches or more, the hearth extension requirements may differ — refer to the install manual's hearth-extension section.
Chimney and venting
An 8-inch chimney flue system is required — larger than the 6-inch used on most EPA-certified freestanding stoves. New factory-built chimney systems must comply with UL 103 HT (USA) or ULC S629 (Canada) and be suitable for solid fuel. Approved manufacturer/brand combinations listed by SBI include American Metal HSS and HS, DuraVent DuraTech / DuraTech Premium / Dura Plus / Dura Plus HTC, Metal Fab Temp Guard, Olympia Rockford and Champion, Ventis (Olympia/SBI Venting Division), Nexvent (SBI Venting Division), Security S-2100+, and Selkirk CF Sentinel / Super Pro 2100 / Super Vent 2100. Verify the chimney brand and component series with your installer before ordering venting.
The minimum chimney height is 15 feet, subject to installer verification, certification label, draft conditions, and local code. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally.
Forced air kit (optional)
The optional Forced Air Kit (SBI VA4460) redirects heat from the fireplace through insulated 6-inch flex ducting (SBI AC01350) to a remote room via a wall or ceiling grille (SBI AC01378). The manufacturer expects at least 25% heat transfer to other rooms when the fireplace is hot and the system is properly designed — shorter runs with fewer deviations work best, longer or overpowered systems can cool the combustion chamber too quickly and cause poor combustion. Use only the manufacturer-supplied forced air system; aftermarket fans and ducting are not safety-tested for this fireplace and present a fire risk.
Outside air
Outside air is not required in conventional homes — combustion air is normally available from room air. However, the optional fresh-air intake register (SBI AC01349) and 25-foot insulated flex pipe (SBI AC02094) plus air intake termination (SBI AC01297) are strongly recommended for tight new-construction homes with mechanical ventilation, for homes with powerful range hoods or other mechanical exhaust appliances, and where local code requires it. A smoke detector and carbon monoxide detector are required in the room where the fireplace is installed.
Code compliance
Code compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the fireplace is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. Zero-clearance wood-burning fireplaces are a regulated category — confirm local requirements before purchasing, particularly in EPA non-attainment counties and in HOA jurisdictions where new wood-burning installs may be restricted.
California Proposition 65
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.
What's in the box, what you'll add
Ships with the fireplace
- Solution 4.5 ZC zero-clearance fireplace with welded steel firebox, double cast-iron-framed glass doors, classic moulded brick panel interior, black faceplate, and listed insulation, shielding, and standoffs that allow installation inside a framed combustible chase per the manual's required clearances, framing dimensions, air spaces, and finish-material zones
- Configured at order with required louver and decorative top panel selection — Traditional Style Louvers (default) or Rustic Style Louvers (upgrade)
- 176 CFM blower with rheostat speed control
- C-Cast baffle and stainless-steel secondary-air tube assembly
- Owner's installation and operation manual and product documentation
Sold separately
- Code-compliant 8-inch Class A insulated chimney system — listed factory-built chimney from an approved manufacturer/brand per the manufacturer's approved-chimney list; required venting components are sold separately
- Hearth extension or floor protection sized to manual specifications, with continuous non-combustible material extending at least 18 inches in front and an R-value ≥ 1.00 — optional Tempered Glass Hearth Pad 10 mm, 18" × 50" (SBI AC02760) is pre-sized for this requirement
- Optional Forced Air Kit (SBI VA4460) — distributes heat to a remote room via insulated ducting; includes 6" × 25' insulated flex pipe (SBI AC01350) and Modern Warm Air Circulation Grille (SBI AC01378); use only manufacturer-supplied components
- Optional 5-inch fresh-air intake register with airtight damper (SBI AC01349) — closable outside-air damper for tight homes or where local code requires it; do not close while the fireplace is in use
- Optional 5" × 25' insulated flex pipe for fresh air intake (SBI AC02094)
- Optional 5" air intake termination with clamps (SBI AC01297) — exterior wall fitting for the fresh-air intake
- Optional 48" wood storage with finishing trim (SBI AC02351) and matching drawer/tool kit (SBI AC02353) — coordinated wood-storage cabinetry
- Digital moisture reader (SBI AC07835) and probe thermometer (SBI AC07840) — strongly recommended; not optional in practice
- Installation by an authorized qualified technician (WETT, NFI, or CSIA certified) and a framing contractor familiar with zero-clearance fireplace chase construction — required for warranty coverage and often required by code, permit, or insurance
How it actually performs
The 95,000 BTU/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 16,900–43,000 BTU/hr band per the CSA B415.1-10 stack-loss method.
A realistic operating day, primary-heat use, cold climate: morning reload at sunrise produces a fast 60–90 minute warm-up and several hours of high output; mid-afternoon reload sustains heat through evening; a full pack at bedtime gives 8–10 hours of useful heat overnight, with the fireplace at coals by morning. In practical use with seasoned oak, maple, or hickory, expect 8–11 hours of useful heat from a packed load. With birch, pine, or softer wood, expect 5–7 hours.
The 25-inch maximum log capacity is generous. Most firewood suppliers cut to 16 inches, which is also the manual's recommended length. Taking up to 25 inches lets you burn longer-cut wood without resawing, useful in regions where supplier cuts run inconsistent or for buyers cutting their own from felled trees. The 17 7/8" firebox depth accepts loading over both width (east-west) and depth (north-south) — north-south loading allows packed overnight cycles with maximum fuel mass.
The included 176 CFM blower meaningfully improves heat distribution into the room and adjacent spaces. Air is distributed from behind the firebox out through the louvers at the top of the unit.
With the optional Forced Air Kit (SBI VA4460) installed and properly sized, the manufacturer expects at least 25% heat transfer to a remote room — typically a bedroom on the same floor, or an adjacent zone of a great-room layout. The kit takes heat that would otherwise stay in the chase and routes it via 6-inch insulated flex pipe to a wall or ceiling grille in another room. Shorter, straighter runs work best; long or twisty runs cool the combustion chamber and reduce both heat output and combustion quality.
The 1.6 g/hr particulate emissions is well below the EPA 2020 cordwood limit of 2.5 g/hr — useful in EPA non-attainment counties and for buyers paying attention to emissions independent of regulatory minimums. The 159 g/hr average CO is higher than the freestanding Solution stoves typically report — a common pattern when comparing zero-clearance fireplaces to freestanding stoves.
The 64% HHV / 69% LHV average efficiency is lower than the Solution-line freestanding stoves (which run 68–72% HHV) — a fireplace fundamentally loses more heat up the chimney than a freestanding stove because the firebox sits inside an insulated chase with limited exposed surface area to radiate into the room. The optimum efficiency at low burn rate (70% LHV / 69% heat transfer) is closer to the freestanding stoves, but average efficiency across a full burn cycle is the realistic operating number.
Air-wash glass on the double doors stays largely clear during proper hot burns. At low burn rates with marginally seasoned wood, the glass will tar. This is universal to non-catalytic tube appliances, not specific to Enerzone, and it is the strongest signal that your wood is too wet or your burn is too cool.
Trade-offs to know
Lower efficiency than freestanding stoves. A wood fireplace at 64% HHV average efficiency is realistically about 5–10 efficiency points lower than the freestanding Solution stoves (68–72% HHV) at comparable firebox volumes. The architectural integration of a built-in fireplace costs heat — less exposed appliance surface to radiate into the room, more heat lost into the chase, longer flue gas paths. Choose a fireplace for the architectural look and the wall-integrated install; choose a freestanding stove if maximum efficiency per cord of wood is the priority.
8-inch chimney is bulkier and pricier. Most EPA-certified non-cat appliances at smaller firebox volumes use a 6-inch chimney. The 8-inch flue here requires a larger framing penetration through the wall or roof and proportionally more expensive chimney material — verify chimney pricing with your installer before committing.
One buyer-configurable choice at order. Only one selection is up to the buyer: louver style — Traditional Style Louvers (default) or Rustic Style Louvers (upgrade). Brick panels and faceplate are included standard, not configurable. Louver style is not field-swappable after order. Walk through the louver choice with the room aesthetic in mind before ordering.
Forced air kit is sold separately. While the 176 CFM blower is included, the Forced Air Kit (VA4460) that redirects heat to a remote room is an additional line item. For multi-room or multi-zone heating, plan the kit cost and the chase pre-routing for the 6-inch flex pipe before framing.
Non-catalytic burn time. A non-cat appliance gives you simpler operation and no catalyst to replace, but you pay for it with shorter burns. The 11-hour maximum claim is achievable on a packed load of dense hardwood with the air shut down hard; useful heat through that cycle is realistically 8–10 hours. For true 14+ hour overnight burns with steady output, a catalytic or hybrid stove is the right tool.
545 lb shipping weight. Heavy enough to require multi-person handling at delivery; the curb-to-chase move is not a one- or two-person job. Confirm framing load and floor support before installation.
Not mobile-home approved. Site-built homes only. Mobile-home and manufactured-home owners need a different appliance category.
Zero-clearance ≠ retrofit into existing masonry fireplace. If you have an existing masonry fireplace and want to upgrade it to an EPA-certified heating appliance, you need a wood insert (Osburn Matrix 2700 or Enerzone Destination 2.7), not a ZC fireplace. A zero-clearance fireplace replaces a framed decorative fireplace or installs in new chase construction — it does not retrofit into a masonry firebox.
Replacement installs require full teardown of the old unit and verification of the chase. Replacing an existing prefab fireplace is not a drop-in swap. The old fireplace and chimney must come out completely, the chase framing must be verified or rebuilt to the required framing dimensions and clearances, and a new approved 8-inch UL 103 HT / ULC S629 chimney must be installed. Plan the renovation scope and installer time accordingly.
Wood quality is not negotiable. The most common "the fireplace doesn't heat" complaint comes from owners running marginally seasoned wood. Secondary combustion works best with dry, properly seasoned fuel, ideally around 15–20% moisture. A digital moisture meter is the single best accessory for this fireplace.
Glass blackens at low burn rates. Universal to non-cat appliances. Daily hot cleanup burns and tolerance for a periodic wipe are part of operating this fireplace. Owners chasing always-clear glass on long, slow burns should look at catalytic technology.
Operating reality
First burns. The first three to six fires release paint VOCs as the high-temperature stove paint cures. The smell can be strong during paint cure-in. Ventilate the room well, avoid prolonged exposure, and expect the odor to disappear after the first several hot burns.
Lighting. The manual describes top-down lighting as an effective method — largest splits on the bottom, smaller above, kindling on top, fire starter at the very top, light the top. Cleaner ignition, less smoke, faster to operating temperature. The wide firebox accommodates a generous top-down stack.
Air control. Full open at light-off, then gradually closed only after the load is fully engaged and stable secondary flames are established. A flue thermometer is strongly recommended — without one, you are guessing at draft, burn rate, and overfire risk. The manual specifies keeping flue temperature in the comfort zone of 250–475 °F at steady state, with 700 °F acceptable transiently during start-up. Do not maintain excessive temperatures over long periods.
Reload cadence. 4–6 hours between reloads in active high-output use; 8–10 hours for a final overnight pack with the air shut hard. Open the air, wait 30 seconds, open the door slowly to avoid spilling smoke into the room. Place at least three pieces on the fire at a time so that the heat radiated from one piece helps ignite the pieces next to it. Normal cordwood loading has no four-log limit — pack the firebox as the loading geometry and burn schedule allow, up to the air-tube level.
Blower management. The blower starts automatically via the included heat sensor when the fireplace reaches operating temperature, typically about an hour after cold start. Turn the rheostat to LO or HI to set speed; the sensor handles on/off. Turn the blower OFF before opening the door fully — otherwise it can blow ash out of the firebox into the room.
Glass cleaning. Damp newspaper dipped in cold ash, or a dedicated ceramic-glass cleaner (SBI AC07825). Daily wipe during low-burn weather; weekly during high-burn. Black streaks at the lower edge mean wet wood; black uniformly across the glass means burns are running too cool. Do not clean the glass when the fireplace is hot, and do not strike or slam the glass doors shut.
Door alignment and gasket replacement. The door gasket needs replacement when the paper-strip test fails: close the door on a strip of paper and try to pull it out; firm resistance means the gasket is sealing, easy pull means it's time to replace. The double-door design has gaskets on both doors and at the meeting edge — test all locations. Plan on gasket replacement every 3–5 seasons in regular use. Gasket and silicone kits and self-adhesive glass gasket are available through the SBI parts network.
Annual chimney sweep. Per the manual, the chimney should be cleaned and inspected at least once each year. Inspect monthly during the heating season until you know your creosote-formation rate; if buildup reaches 1/8 inch, sweep immediately. Heavy burners or those with marginally seasoned wood may need mid-season cleaning. The 8-inch chimney requires sweep tools sized for 8-inch flue — verify your sweep is equipped for the larger diameter.
Wood seasoning. Hardwood needs 12–24 months split, stacked off the ground, top-covered, with sun and wind on the sides. Don't trust supplier "seasoned" claims — use the SBI digital moisture reader (AC07835), split a piece in half, measure the fresh face. Manual target: 15–20% moisture. Wood above 25% will smolder, soot the glass, line the chimney with creosote, and undercut every published efficiency and emissions number on this page.
Manufactured logs (composite firelogs). Per the manual, only manufactured logs made of 100% wood residues are permitted (no logs containing chemicals or accelerants). Start with one log and gradually increase; never put more than four logs in at a time; logs must be average size and not exceed 8 inches in diameter. Manufactured logs release a large heat output over a short period — over-loading risks damaging the firebox. This four-log limit applies only to manufactured/composite firelogs and not to normal split cordwood.
Blower maintenance. Keep the blower intake and fins free of dust and follow the blower kit instructions for service. Do not oil the blower unless the blower manual specifically calls for lubrication. Replacement blowers and related service parts are available through Enerzone/SBI dealers and parts channels if needed years out.
What never to burn. Per the manual and EPA fuel rules: no coal, garbage, yard waste, materials containing rubber or plastic, waste petroleum products, paint or paint thinners, asphalt products, painted or pressure-treated wood, railroad ties, pallets, manure or animal remains, plywood, particle board, paper products, asbestos materials, construction or demolition debris, salt-water driftwood, kerosene, diesel fuel, or unseasoned wood. This does not prohibit normal fire starters made from paper, cardboard, sawdust, wax, or similar substances when used only to start a fire. Burning prohibited materials destroys the firebox, voids the warranty, and releases toxic compounds into your home and the chimney.
Warranty and service
The Enerzone limited lifetime warranty applies to the original retail purchaser only and is non-transferable. The warranty applies to normal residential use only. Proof of purchase (dated bill of sale), model name, and serial number are required for any warranty claim. Online registration is recommended at enerzone-intl.com but not required if a dated invoice is retained.
Coverage by component
A one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.
Warranty claims are made through your Enerzone dealer and remain subject to SBI/Enerzone inspection, approval, and the current written warranty. Kaminos is the retailer for this fireplace and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer. SBI's parts network is well-stocked — replacement bricks, baffle, secondary tubes, glass, gaskets, blower, faceplate, louvers, and venting components are openly available at fair prices through multiple parts vendors.
Enerzone may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.
Coverage details can change by component and warranty revision; the current Enerzone warranty controls.
Compare with
A built-in workhorse, not a decorative fireplace. If you're framing a chase, willing to pay for an 8-inch chimney, and want serious EPA-certified heating output behind a wide rectangular glass — it heats. That is the entire promise.
If you have any questions about this product, please let us know by filling out the form below, and we will contact you as soon as possible.
- Choosing a selection results in a full page refresh.