At a glance
- Type: Wood stove, EPA 2020 certified
- Heats: 250–1,200 sq ft
- Heat output: 45,000 BTU/hr
- Log length: 16 in north-south
- Efficiency: 74% HHV / 79% LHV
- Burn time: Up to 5 hours
- Chimney: 6 in
Description
The Osburn 950 Wood Stove is an EPA 2020 certified wood stove for 250 to 1,200 sq ft. It burns up to 5 hours on a load and takes a 6-inch chimney.
Who it's for
Right buyer. Owners of small homes, cabins, sunrooms, additions, finished basements, studio cottages, or one-room living spaces where wood-burning installation is permitted, roughly 250–900 sq ft, with reasonable insulation and access to seasoned hardwood at 15–20% moisture content.
The Osburn 950 shares the same SBI small-stove performance platform as the Enerzone Solution 1.4: same firebox volume, same heat output, same efficiency, same emissions, same 17-inch north-south log capacity.
How it performs
The 45,000 BTU/hr maximum is a peak rating, transient, achieved on dry cordwood at high loading density and short reload intervals. The figure that matters for daily life is the sustained output across a full burn cycle, which lands in the 12,000–27,000 BTU/hr band per the CSA B415.1-10 stack-loss method.
Good to know
- Same platform as the Enerzone Solution 1.4.
- Small firebox, short burns.
- The 1,200 sq ft figure is aspirational. The most consistent owner regret across small wood stoves is buying for the high end of the manufacturer's heating range.
Specifications
Dimensions
Dimensions from the specification sheet
| Measurement | Value |
|---|---|
| Overall height | 28‑7/8" |
| Overall width | 20‑1/4" |
| Overall depth | 27‑7/8" |
| Shipping weight | 317 shipping lb |
| Glass, W x H | 10‑1/4 x 8‑7/8 |
| Door opening | 12 W x 7‑5/8 H |
| Firebox, W x H x D | 14‑1/4 W x 11‑3/4 H x 19‑1/8 D |
Dimensions
| Measurement | Value |
|---|---|
| Firebox volume | 1.8 ft³ overall / 1.55 ft³ EPA |
| Glass | Ceramic, 5/32" thick |
| Stove dimensions | 20 1/4" W x 27 7/8" D x 28 7/8" H |
| Door opening | 12" W x 7 5/8" H |
| Shipping weight | 317 lb |
Where it can go
The Osburn 950 is approved for installation in residential homes, cabins, sunrooms, alcoves (with double-wall pipe connector), and mobile or manufactured homes (with the required fresh-air intake kit and insulated intake pipe). It is not approved for installation in factory-built (prefab) metal fireplaces or in any outdoor or unconditioned space.
Clearances to combustibles
Floor protection
For the Osburn 950, the manual specifies no R-factor required for floor protection — only a continuous, non-combustible material. Approved materials include steel of at least 0.015" thickness, ceramic tiles sealed together with grout (over a continuous non-combustible sheet beneath), cement board, brick, or any other approved or listed material suited for floor protection. Tile alone is not sufficient — a continuous non-combustible sheet beneath the tile is required.
Floor protection dimensions per the manual: in Canada, 18 inches forward of the door opening and 8 inches each side; in the USA, 16 inches forward of the door opening and 8 inches each side. No floor protection is required if the stove is installed on a non-combustible floor (concrete slab, for example).
Clearances
United States figures, in inches. The rating plate on the appliance overrides any published number; the installer confirms on site.
| Clearance | Minimum |
|---|---|
| Back wall, single-wall pipe | 13" |
| Back wall, double-wall pipe | 6" |
| Corner, single-wall pipe | 12" |
| Corner, double-wall pipe | 12" |
| Side wall | 10" |
| Ceiling, from the floor the stove sits on | 84" |
Notes from the manual
The manual specifies clearances based on whether single-wall or double-wall pipe connector is used, and adjusts further for heat-shielded installations and lowered ceilings. With a single-wall pipe connector in a USA installation, the basic clearances are 12" rear (A), 12" side (B), and 11" corner (C). With a double-wall pipe connector, those drop to 6" / 12" / 6" respectively. With heat shield AC02762 and a double-wall connector, clearances reduce further to 2 1/2" on rear, side, and corner measurements, except where the clearance reduction is on the same side as the door handle; in that case, the manual requires at least 6" from the side wall. Reduced clearances may also be achieved using approved wall heat-shield construction described in the manual; the construction rules and reduction percentages are specific and should be reviewed with your installer before purchase.
Always confirm the binding clearance figures against the certification label on the back of the stove and your local code. The manual's clearance tables include separate values for Canada and USA, single- and double-wall pipe, with and without heat shields, lowered ceilings, alcoves, and mobile homes.
Documents
- Wood stove manual | Safety notifications & general information (PDF - 2.9 MB)
- Osburn 950 wood stove installation & operation requirements (PDF - 3.7 MB)
- Osburn 950 Dimensions (PDF - 0.2 MB)
- Maximum recommended heating area by climate zone (PDF)
- Osburn wood products brochure, USA edition, with dimension drawings (PDF)
- Osburn limited lifetime warranty
- EPA test reports
- Replacement parts
Details
| Combustion technology | Non-catalytic |
|---|---|
| Firebox volume | 1.8 ft³ overall / 1.55 ft³ EPA |
| Maximum heat output | 45,000 BTU/hr |
| Tested output range | 12,124–26,700 BTU/hr |
| Heating range | 250–1,200 sq ft |
| Average efficiency | 74% HHV / 79% LHV |
| Particulate emissions | 1.8 g/hr |
| Maximum burn time | Up to 5 hours |
| Recommended log length | 16 in north-south |
| Maximum log length | 17 in north-south |
| Construction | Carbon steel, cast-iron door |
| Notable features | Heat shield + deflector |
| Baffle | C-Cast |
| Glass | Ceramic, 5/32" thick |
| Blower | Optional, up to 100 CFM |
| Flue connection | 6 in |
| Stove dimensions | 20 1/4" W x 27 7/8" D x 28 7/8" H |
| Combustion chamber | 14 1/4" W x 19 1/8" D x 11 3/4" H |
| Door opening | 12" W x 7 5/8" H |
| Shipping weight | 317 lb |
| Mobile home approved | Yes |
| Alcove install approved | Yes |
| Country of origin | Made in Canada |
| Model | OB00950 |
| Manufacturer | Osburn, by Stove Builder International (SBI), Quebec, Canada |
| Certification | UL 1482, UL 737, ULC S627; EPA 2020; CSA B415.1‑10 |
| Warranty | Limited lifetime |
| Specification source | SBI specification table as published by Osburn dealers (thetorchguys.com, ruralenergy.com, buildwithrise.com), 2026 |
Warranty
A one-time replacement limit applies to all parts with lifetime coverage. Warranty is void if the unit is used to burn anything other than seasoned cordwood, or if it is not operated according to the owner's manual. Damage caused by misuse, improper installation, lack of maintenance, overfiring, downdrafts, venting problems, or under-estimated heating area is not covered. Improper installation by anyone other than an authorized qualified technician voids the warranty.
Warranty claims are made through your Osburn dealer and remain subject to SBI/Osburn inspection, approval, and the current written warranty. Kaminos is the retailer for this stove and supports buyers through purchase; final warranty approval rests with SBI as the manufacturer. SBI's parts network is well-stocked — replacement bricks, baffle, secondary tubes, glass, gaskets, and optional blower are openly available at fair prices through multiple parts vendors.
Osburn may require photos or returned parts to support a claim; repair work covered by warranty requires prior manufacturer approval.
Coverage details can change by component and warranty revision; the current Osburn warranty controls.
Heat
From the specification sheet
| Spec | Value |
|---|---|
| Heating area | 250 to 1,200 sq ft |
| Maximum heat output | 45,000 BTU/h |
| Heat output range | up to 26,700 BTU/h overall |
| Efficiency | 74% HHV, 79% LHV average; 80% optimum |
| Burn time | 5 h |
| Firebox volume | 1.8 cu ft |
| Log length | 17 in (loads over depth) |
| Emissions | 1.8 g/h |
| Blower | optional |
| Spec | Value | What it means |
|---|---|---|
| Combustion technology | Non-catalytic | Secondary-air tubes reignite smoke gases. No catalyst to replace; one air-control lever; simpler operation than a cat stove but shorter low-and-slow burn times. |
| Maximum heat output | 45,000 BTU/hr | Peak output on dry cordwood, transient. Sustained output across a burn cycle is substantially lower. |
| Heating range | 250–1,200 sq ft | Manufacturer's stated range. Real-world comfort sizing for primary heat is roughly 400–900 sq ft in moderate climates and lower in cold climates or older homes — depends on insulation, layout, climate, ceiling height, fuel quality, and installation. |
| Average efficiency | 74% HHV / 79% LHV | 80% optimum efficiency at low burn rate. HHV is the federal standard. Government incentives may apply by jurisdiction and installation date. |
| Particulate emissions | 1.8 g/hr | EPA 2020 limits are 2.0 g/hr crib-wood or 2.5 g/hr cordwood. The stove is listed as compliant with the 2020 cordwood standard. |
| Maximum burn time | Up to 5 hours | Manufacturer maximum at the lowest air setting. Useful heat through a burn cycle is realistically 3–4 hours. |
| Recommended log length | 16 in north-south | Per manual. Most firewood suppliers cut to this length. |
| Maximum log length | 17 in north-south | Limited margin over 16-inch supply cuts. Verify your firewood supply before buying. |
| Combustion chamber | 14 1/4" W x 19 1/8" D x 11 3/4" H | Inside firebox dimensions. The depth-loading orientation (N-S) means logs run front-to-back over the 19 1/8" depth. |
Choices and prices
Options
The unit price is Osburn's 2026 list price for the wood stove alone. Options sold on this page add to it; those marked on request we add to your order by hand.
Blower
| Blower | Part | Price |
|---|---|---|
| BLOWER WITH THERMODISC (on request) | AC02023 | $300 |
Fresh air
| Fresh air | Part | Price |
|---|---|---|
| 5''Ø FRESH AIR INTAKE REGISTER WITH AIRTIGHT DAMPER (on request) | AC01349 | $285 |
| 5"Ø FRESH AIR INTAKE KIT FOR WOOD STOVE (on request) | AC01421 | $165 |
| 5"Ø X 4' INSULATED FLEX PIPE FOR FRESH AIR INTAKE (on request) | AC02090 | $50 |
Other options
| Other options | Part | Price |
|---|---|---|
| RIGID FIRESCREEN (on request) | AC01420 | $175 |
| TEMPERED GLASS HEARTH PAD 10 mm - 54" X 46 3/4" (on request) | AC02703 | $869 |
| MODULAR FLOOR PROTECTION SYSTEM 54" X 46 3/4" (on request) | AC02711 | $545 |
| TINTED TEMPERED GLASS HEARTH PAD 10 mm - 54" X 46 3/4" (on request) | AC02758 | $439 |
| BLACK STEEL HEARTH PAD 60'' - CORNER (on request) | AC02790 | $575 |
What arrives
- Osburn 950 wood stove with welded carbon-steel firebox and cast-iron glazed door
- Decorative side panels
- Stainless-steel heat shield over the C-Cast firestop
- Top heat deflector that redirects heat toward the front of the stove
- High-density refractory firebrick lining
- C-Cast baffle and stainless-steel secondary-air tube assembly
- Owner's manual and product documentation
Sold separately
- Code-compliant 6-inch chimney system — listed factory-built chimney for new installations, or an approved masonry chimney/liner configuration where permitted by code and verified by the installer/AHJ; required venting components are sold separately
- Single-wall or double-wall pipe connector between the stove and chimney — double-wall is required for alcove and mobile-home installations and reduces clearance requirements
- Hearth pad or floor protection sized to manual specifications, with continuous non-combustible sheet beneath any tile
- Optional 100 CFM blower with thermodisc heat sensor (SBI AC02023) — adds forced-air circulation to improve heat distribution; without it, heat moves by radiation and natural convection only
- Optional 5-inch fresh-air intake kit (SBI AC01421) — required for mobile-home installations and for code or mechanical-ventilation requirements
- 5-inch insulated flex pipe for fresh-air intake (SBI AC02090 or equivalent ULC S110 / UL 181 class 0 or class 1 insulated HVAC pipe) — required for mobile-home installations
- Optional 5-inch fresh-air intake register with airtight damper (SBI AC01349) — useful where local code, airtight-home design, or owner preference calls for a closable outside-air damper; do not close while the stove is in use
- Optional rigid fire screen (SBI AC01420) — not permitted for open-door use in the United States or in Canadian provinces/jurisdictions with particulate-emission limits; never permitted for use in a mobile home; never leave the stove unattended when used with a fire screen
- Optional heat shield AC02762 for further clearance reductions to 2 1/2" on rear, side, and corner measurements (subject to the door-handle 6" side-wall exception)
- Pin-type wood moisture meter — not optional in practice
- Stove-top or flue thermometer — strongly recommended; not optional in practice
- Installation by an authorized qualified technician (WETT, NFI, or CSIA certified) — required for warranty coverage and often required by code, permit, or insurance
Installation
Chimney requirements from the specification sheet
| Requirement | Value |
|---|---|
| Flue | 6 in |
| Chimney type | CAN/ULC S629, UL 103 HT |
| Minimum chimney height | 12 ft |
| Alcove installation | yes |
| Mobile home installation | yes, with fresh air intake |
| Flue center | 6‑5/8 in from the back, 10‑1/8 in from the side |
The Osburn 950 performs best on a 6-inch chimney flue system. New factory-built chimney systems must comply with UL 103 HT (USA) or ULC S629 (Canada) and be suitable for solid fuel. The stove may also be connected to a code-compliant masonry chimney, provided the chimney has either a clay liner or a suitably listed stainless-steel liner and the application is verified by a qualified installer. Per the manual, minimum chimney height is 12 feet. The chimney must extend at least 3 feet above the highest point of contact with the roof and at least 2 feet above any roof line or obstacle within 10 feet horizontally, subject to local code and installer verification.
For mobile-home installations, single-wall pipe is strictly forbidden — only double-wall pipe is permitted, and a fresh-air intake kit with insulated intake pipe is required. The fresh-air intake pipe (HVAC type) must meet ULC S110 or UL 181 class 0 or class 1.
Outside air
An optional fresh-air intake kit is available for code jurisdictions requiring outside combustion air, for tight new-construction homes with mechanical ventilation, and is required for mobile-home installations. Use the AC01421 5-inch fresh-air intake kit for this stove. Mobile-home installations also require insulated 5-inch flex pipe such as AC02090 or equivalent ULC S110 / UL 181 class 0 or class 1 insulated HVAC pipe. The AC01349 airtight fresh-air intake register is an optional closable damper accessory for installations where local code, airtight-home design, or owner preference calls for one; do not close it while the stove is in use. A smoke detector and carbon monoxide detector are required in the room where the stove is installed.
Codes and approvals
Code compliance for any specific installation is determined by the local Authority Having Jurisdiction. Manufacturer listings cover what the stove is approved for; the AHJ approves what is permitted at your address. A WETT (Canada), NFI, or CSIA (USA) certified installer is strongly recommended and frequently required by code, permit, or insurance. Confirm local requirements before purchasing — particularly in EPA non-attainment counties and in HOA jurisdictions where new wood-burning installs may be restricted.
California Proposition 65
This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.
Planning the install
- Check with your building department and insurer: wood appliances need a permit in most places and an inspection after installation.
- The chimney is the other half of the system. It is sold separately and quoted from your installer's plan.
- Clearances and floor protection come from the manual and depend on the pipe and shields you choose. Send us your plan and we will check it.
- Burn seasoned wood below 20 percent moisture. Wet wood is the cause of most complaints about any wood stove.
- Special-order goods ship by freight.
Questions
How does it compare with the other Osburn models?
- Enerzone Solution 1.4 Same SBI small-stove performance platform — same firebox, same heat output, same efficiency, same emissions, same 17" N-S log capacity, same warranty schedule. The difference between the two is brand finish, styling package, and dealer/parts positioning rather than a different heat-output class. Choose by the brand and finish you prefer. Osburn 1700 Osburn step-up model with a larger firebox (1.86 ft³ overall / 1.44 ft³ EPA), higher peak output (65,000 BTU/hr), 18-inch log capacity, more heating area (500–1,800 sq ft), and optional 130 CFM blower. Choose the Osburn 1700 if you need more heating output and longer logs; choose the Osburn 950 for compact installations and tighter spaces where the smaller footprint and reduced clearances matter.
- Pacific Energy Vista LE Premium cross-brand small stove. Sealed-firebox technology, longer real-world burn potential, premium build, higher price. Step-up choice for buyers who want the best small-stove operation and are willing to pay for it.
What chimney does it take?
A 6-inch flue: a listed factory-built chimney rated UL 103 HT in the US or ULC S629 in Canada, or a lined masonry chimney in good repair. The connector pipe and chimney are quoted from your installer's plan.
Does it need a blower?
No. Every Osburn heats by radiation and natural convection. The optional blower moves warm air into the room faster and helps in a larger or open space; it needs a 120-volt outlet.
Can I install it myself?
Many owners do the placement and the pipe with the manual in hand, but the chimney, the permit and the inspection are where an installer earns the fee. Insurance usually requires the inspection.
Can I return it?
Stoves ship by freight. Confirm the model and the options with us before you order, and contact us before returning anything.
What wood should I burn?
Seasoned hardwood, split and dried a year or more, below 20 percent moisture. Wet wood smokes, coats the chimney with creosote and makes a poor fire.
If you have any questions about this product, please let us know by filling out the form below, and we will contact you as soon as possible.
- Choosing a selection results in a full page refresh.